EPC Price Check

Does a C-or-better EPC sell for more in L40 9 (West Lancashire)?

No measurable EPC premium here. In postcode sector L40 9 (West Lancashire), comparing like with like — same floor area, property type, build period and year of sale — the difference is −4.2% (95% range −10.9% to +3.1%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 16% more per square metre than D–G homes (median £2,821 vs £2,439, 247 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−4.2%like-for-like: no measurable difference (95% range −10.9% to +3.1%)
+16%raw gap per m² (before like-for-like)
247sales matched to a certificate
57%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 142 m² against 114 m² for D–G; the most common build period is 2012 onwards for C+ and 1930–1949 for D–G; 92% of C+ and 96% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+16%—
Whole price, nothing held equal+33.4%+18.6% to +50.1%
Same floor area+13.2%+5.5% to +21.4%
+ same property type+7.5%+0.6% to +14.8%
+ same build period+0.5%−7.0% to +8.7%
+ same year of sale−4.2%−10.9% to +3.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in L40 9

EPC band (last certificate before sale)SalesMedian £ per m²
B38£3,166
C51£2,549
D114£2,452
E35£2,412
F6too few
G3too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached66£2,98663£2,550
Semi-detached16£2,30589£2,318
Terraced7—6—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector L40 9247−4.2%−10.9% to +3.1%
District L403,673−0.8%−2.8% to +1.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in L40 9 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)31 (515 meters)
Median gas use per meter (median of postcodes)13,529 kWh
Gas-heated homes with an EPC350
Energy implied by their certificates (median)20,644 kWh
Metered gas as a share of the certificate figure (median of 29 postcodes)57% (middle half 50%–65%)

Certificates by band imply: B 10,377 kWh (45 homes) · C 14,985 kWh (112 homes) · D 23,794 kWh (138 homes) · E 34,858 kWh (44 homes) · F 40,897 kWh (10 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in L40 9?

About 320 of the 350 gas-heated homes with an energy certificate in L40 9 (92%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 4 of the 20 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector20
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 2,240 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,320
Gas-heated homes with an EPC on these substations350
Of them, could switch within the spare capacity≈ 320 (92%)
…if each heat pump adds 3 kW (a cold snap)≈ 250 (72%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

247 of 259 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats