EPC Price Check

Does a C-or-better EPC sell for more in L40 3 (Chorley)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector L40 3 (Chorley), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district L40 as a whole the like-for-like difference is −0.8% (95% range −2.8% to +1.2%). The raw gap is bigger: C+ homes sold for 3% less per square metre than D–G homes (median £3,200 vs £3,291, 134 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−0.8%like-for-like in district L40 (95% range −2.8% to +1.2%); too few sales in this sector
−3%raw gap per m² (before like-for-like)
134sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 134 m² against 120 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 95% of C+ and 94% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in L40 3

EPC band (last certificate before sale)SalesMedian £ per m²
A12£3,161
B33£3,214
C17£3,325
D40£3,745
E17£3,094
F13£2,459
G2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached51£3,18541£3,146
Semi-detached8—27£3,604
Terraced3—4—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector L40 3134too few—
District L403,673−0.8%−2.8% to +1.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in L40 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)11 (216 meters)
Median gas use per meter (median of postcodes)14,856 kWh
Gas-heated homes with an EPC148
Energy implied by their certificates (median)19,571 kWh
Metered gas as a share of the certificate figure (median of 10 postcodes)61% (middle half 58%–74%)

Certificates by band imply: B 8,726 kWh (49 homes) · C 20,938 kWh (27 homes) · D 26,280 kWh (51 homes) · E 39,360 kWh (12 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in L40 3?

About 140 of the 148 gas-heated homes with an energy certificate in L40 3 (94%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 3 of the 19 local substations would fill up before every gas-heated home they supply could switch; 3 are already at or over capacity.

Local (street) substations serving homes in the sector19
Already at or over capacity3 (16%)
Their combined spare capacity (demand headroom)≈ 2,220 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,310
Gas-heated homes with an EPC on these substations148
Of them, could switch within the spare capacity≈ 140 (94%)
…if each heat pump adds 3 kW (a cold snap)≈ 100 (70%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

134 of 153 house and flat sales in the sector since 2015 (88%) were matched to a certificate.

How this is calculated

Caveats