EPC Price Check

Does a C-or-better EPC sell for more in L40 2 (Chorley)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector L40 2 (Chorley), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district L40 as a whole the like-for-like difference is −0.8% (95% range −2.8% to +1.2%). The raw gap is different: C+ homes sold for 8% more per square metre than D–G homes (median £2,851 vs £2,645, 197 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−0.8%like-for-like in district L40 (95% range −2.8% to +1.2%); too few sales in this sector
+8%raw gap per m² (before like-for-like)
197sales matched to a certificate
62%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 146 m² against 107 m² for D–G; the most common build period is 2012 onwards for C+ and 1967–1975 for D–G; 76% of C+ and 86% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in L40 2

EPC band (last certificate before sale)SalesMedian £ per m²
B22£3,185
C46£2,639
D80£2,645
E35£2,476
F12£2,788
G2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached43£2,89864£2,801
Semi-detached9—47£2,439
Terraced14£2,48018£2,253
Flat / maisonette2—0—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector L40 2197too few—
District L403,673−0.8%−2.8% to +1.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in L40 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)26 (486 meters)
Median gas use per meter (median of postcodes)13,376 kWh
Gas-heated homes with an EPC304
Energy implied by their certificates (median)19,188 kWh
Metered gas as a share of the certificate figure (median of 22 postcodes)62% (middle half 58%–70%)

Certificates by band imply: B 9,438 kWh (39 homes) · C 15,419 kWh (107 homes) · D 22,247 kWh (122 homes) · E 34,633 kWh (32 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in L40 2?

Yes, on SP Electricity North West's figures: the local substations serving L40 2 have enough spare capacity for all 304 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 15 local substations would fill up first.

Local (street) substations serving homes in the sector15
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 2,560 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,510
Gas-heated homes with an EPC on these substations304
Of them, could switch within the spare capacity≈ 300 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 240 (79%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

197 of 222 house and flat sales in the sector since 2015 (89%) were matched to a certificate.

How this is calculated

Caveats