EPC Price Check

Does a C-or-better EPC sell for more in CA28 8 (Cumberland)?

A small premium for a better EPC here. In postcode sector CA28 8 (Cumberland), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.2% more (95% range +0.6% to +7.9%). The raw gap is bigger: C+ homes sold for 17% more per square metre than D–G homes (median £1,548 vs £1,328, 1,354 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.2% ▲like-for-like: small premium (95% range +0.6% to +7.9%)
+17%raw gap per m² (before like-for-like)
1,354sales matched to a certificate
57%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 89 m² against 84 m² for D–G; both groups are most often built in 1950–1966; 76% of C+ and 71% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+17%—
Whole price, nothing held equal+39.0%+31.1% to +47.3%
Same floor area+19.4%+14.9% to +24.1%
+ same property type+15.9%+11.9% to +20.0%
+ same build period+5.7%+1.7% to +9.8%
+ same year of sale+4.2%+0.6% to +7.9%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in CA28 8

EPC band (last certificate before sale)SalesMedian £ per m²
A4too few
B52£1,797
C317£1,471
D776£1,364
E172£1,138
F29£1,246
G4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached103£1,724105£1,781
Semi-detached180£1,536596£1,332
Terraced85£1,500264£1,148
Flat / maisonette5—16£1,634

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CA28 81,354+4.2%+0.6% to +7.9%
District CA285,2190.0%−2.0% to +2.1%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CA28 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)187 (3,498 meters)
Median gas use per meter (median of postcodes)10,638 kWh
Gas-heated homes with an EPC2,213
Energy implied by their certificates (median)18,657 kWh
Metered gas as a share of the certificate figure (median of 180 postcodes)57% (middle half 49%–66%)

Certificates by band imply: B 9,166 kWh (56 homes) · C 13,978 kWh (635 homes) · D 19,253 kWh (1,240 homes) · E 28,714 kWh (248 homes) · F 45,927 kWh (28 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CA28 8?

About 1,700 of the 2,212 gas-heated homes with an energy certificate in CA28 8 (77%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 8 of the 47 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector47
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 7,590 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,460
Gas-heated homes with an EPC on these substations2,212
Of them, could switch within the spare capacity≈ 1,700 (77%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,420 (64%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,354 of 1,425 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats