EPC Price Check

Does a C-or-better EPC sell for more in CA14 5 (Cumberland)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector CA14 5 (Cumberland), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district CA14 as a whole the like-for-like difference is +2.4% (95% range +0.2% to +4.7%). The raw gap is bigger: C+ homes sold for 72% more per square metre than D–G homes (median £1,893 vs £1,098, 945 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+2.4%like-for-like in district CA14 (95% range +0.2% to +4.7%); too few sales in this sector
+72%raw gap per m² (before like-for-like)
945sales matched to a certificate
57%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 89 m² against 86 m² for D–G; the most common build period is 2012 onwards for C+ and 1950–1966 for D–G; 82% of C+ and 53% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in CA14 5

EPC band (last certificate before sale)SalesMedian £ per m²
B176£1,983
C185£1,739
D361£1,192
E175£994
F35£1,005
G13£659

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached162£1,98049£2,005
Semi-detached135£1,846259£1,179
Terraced59£1,464274£987
Flat / maisonette5—2—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector CA14 5945too few—
District CA146,142+2.4%+0.2% to +4.7%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in CA14 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)179 (3,196 meters)
Median gas use per meter (median of postcodes)9,831 kWh
Gas-heated homes with an EPC2,410
Energy implied by their certificates (median)15,664 kWh
Metered gas as a share of the certificate figure (median of 170 postcodes)57% (middle half 46%–66%)

Certificates by band imply: A 1,997 kWh (17 homes) · B 9,422 kWh (158 homes) · C 13,283 kWh (997 homes) · D 18,655 kWh (969 homes) · E 29,827 kWh (246 homes) · F 38,389 kWh (19 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in CA14 5?

About 1,150 of the 2,410 gas-heated homes with an energy certificate in CA14 5 (48%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 11 of the 36 local substations would fill up before every gas-heated home they supply could switch; 6 are already at or over capacity.

Local (street) substations serving homes in the sector36
Already at or over capacity6 (17%)
Their combined spare capacity (demand headroom)≈ 7,680 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,520
Gas-heated homes with an EPC on these substations2,410
Of them, could switch within the spare capacity≈ 1,150 (48%)
…if each heat pump adds 3 kW (a cold snap)≈ 980 (41%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

945 of 978 house and flat sales in the sector since 2015 (97%) were matched to a certificate.

How this is calculated

Caveats