Does a C-or-better EPC sell for more in BD21 2 (Bradford)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector BD21 2 (Bradford), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district BD21 as a whole the like-for-like difference is +5.7% (95% range +2.0% to +9.6%). The raw gap is bigger: C+ homes sold for 32% more per square metre than D–G homes (median £1,250 vs £949, 547 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+5.7%like-for-like in district BD21 (95% range +2.0% to +9.6%); too few sales in this sector
+32%raw gap per m² (before like-for-like)
547sales matched to a certificate
47%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 79 m² against 82 m² for D–G; the most common build period is 1950–1966 for C+ and before 1900 for D–G; 46% of C+ and 31% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in BD21 2

EPC band (last certificate before sale)SalesMedian £ per m²
B2too few
C67£1,279
D275£1,153
E161£789
F21£757
G21£642

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached1—14£2,012
Semi-detached31£1,373133£1,424
Terraced36£1,153316£793
Flat / maisonette1—15£729

Compared with the wider area

AreaSalesLike-for-like95% range
Sector BD21 2547too few—
District BD212,867+5.7%+2.0% to +9.6%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in BD21 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)113 (1,979 meters)
Median gas use per meter (median of postcodes)11,559 kWh
Gas-heated homes with an EPC1,649
Energy implied by their certificates (median)25,195 kWh
Metered gas as a share of the certificate figure (median of 111 postcodes)47% (middle half 35%–60%)

Certificates by band imply: B 11,466 kWh (10 homes) · C 13,189 kWh (330 homes) · D 21,879 kWh (729 homes) · E 38,896 kWh (516 homes) · F 51,227 kWh (43 homes) · G 65,325 kWh (21 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in BD21 2?

About 950 of the 1,451 gas-heated homes with an energy certificate in BD21 2 (65%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 7 of the 25 local substations would fill up before every gas-heated home they supply could switch; 2 are already at or over capacity.

Local (street) substations serving homes in the sector25
Already at or over capacity2 (8%)
Their combined spare capacity (demand headroom)≈ 8,180 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,810
Gas-heated homes with an EPC on these substations1,451 (88% of the sector's)
Of them, could switch within the spare capacity≈ 950 (65%)
…if each heat pump adds 3 kW (a cold snap)≈ 790 (55%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

547 of 582 house and flat sales in the sector since 2015 (94%) were matched to a certificate.

How this is calculated

Caveats