EPC Price Check

Solar panels, heat pumps and insulation in Thursley conservation area

In the Thursley conservation area (Waverley), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 28 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 46 homes inside the boundary have an energy certificate: 37% are solid-wall homes with no wall insulation, 2% heat with a gas boiler and 93% are rated D–G; 5 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

46homes with an energy certificate
37%solid walls, no insulation
2%heated by a gas boiler
5heat pumps

Article 4: Waverley publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Thursley

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 46)

WallsHomesShare
Solid wall (brick or stone), no insulation1737%
Cavity wall, unfilled1430%
Cavity wall, filled817%
Solid wall, internal insulation49%
Cavity wall, insulated (as built or unspecified)24%
Timber frame12%
HeatingHomesShare
Oil2146%
Electric (storage heaters, panels, boiler)1533%
Heat pump511%
LPG49%
Gas boiler12%
Loft / roof insulationHomesShare
No insulation511%
Under 200 mm1022%
200 mm or more1839%
Insulated (depth not recorded)920%
Flat or other home above37%
Other12%
WindowsHomesShare
Double glazed3576%
Single glazed715%
Secondary glazing49%

Energy rating: B 1 (2%) · C 2 (4%) · D 14 (30%) · E 16 (35%) · F 12 (26%) · G 1 (2%). Houses and bungalows: 85% of the homes; solar panels on 4% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1970.

Compared with Waverley and England

Share of homesThursleyAll 44 areas in WaverleyEngland
Solid walls, no insulation37%37.8%48.7%
Gas boiler2%74.3%66.4%
Rated D–G93%—56.5%

Caveats

All conservation areas in Waverley · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker