EPC Price Check

Solar panels, heat pumps and insulation in Elstead conservation area

In the Elstead conservation area (Waverley), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. The area has 11 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 58 homes inside the boundary have an energy certificate: 36% are solid-wall homes with no wall insulation, 90% heat with a gas boiler and 67% are rated D–G; 0 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

58homes with an energy certificate
36%solid walls, no insulation
90%heated by a gas boiler
0heat pumps

Article 4: Waverley publishes its Article 4 areas on planning.data.gov.uk and none overlaps this area; a direction can still exist on paper, so check with the council.

What needs planning permission in Elstead

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 58)

WallsHomesShare
Solid wall (brick or stone), no insulation2136%
Cavity wall, insulated (as built or unspecified)814%
Cavity wall, unfilled814%
Cavity wall, filled610%
Cavity wall, partly insulated610%
Modern wall (U-value from the design)47%
Cavity wall, internal or external insulation23%
Solid wall, insulated23%
Solid wall, internal insulation12%
HeatingHomesShare
Gas boiler5290%
Electric (storage heaters, panels, boiler)59%
LPG12%
Loft / roof insulationHomesShare
No insulation47%
Under 200 mm1831%
200 mm or more2034%
Insulated (depth not recorded)1221%
Other47%
WindowsHomesShare
Double glazed4578%
Single glazed814%
Secondary glazing59%

Energy rating: B 6 (10%) · C 13 (22%) · D 26 (45%) · E 12 (21%) · F 1 (2%). Houses and bungalows: 90% of the homes; solar panels on 2% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1974.

Compared with Waverley and England

Share of homesElsteadAll 44 areas in WaverleyEngland
Solid walls, no insulation36%37.8%48.7%
Gas boiler90%74.3%66.4%
Rated D–G67%—56.5%

Caveats

All conservation areas in Waverley · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker