EPC Price Check

Solar panels, heat pumps and insulation in Sloane Square conservation area

In the Sloane Square conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area but deals with other things (such as changes of use); it does not change the rules below. The area has 18 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 973 homes inside the boundary have an energy certificate: 80.1% are solid-wall homes with no wall insulation, 75.7% heat with a gas boiler and 52.5% are rated D–G; 33 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

973homes with an energy certificate
80.1%solid walls, no insulation
75.7%heated by a gas boiler
33heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area but deals with other things (such as changes of use); it does not change the rules below. (Article 4 - No 100; Article 4 - No 106)

What needs planning permission in Sloane Square

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 973)

WallsHomesShare
Solid wall (brick or stone), no insulation77980.1%
Solid wall, internal insulation484.9%
Timber frame474.8%
Cavity wall, unfilled282.9%
Modern wall (U-value from the design)262.7%
Other or not known161.6%
Cavity wall, insulated (as built or unspecified)151.5%
Solid wall, partly insulated70.7%
Cavity wall, partly insulated30.3%
Solid wall, insulated20.2%
Cavity wall, filled10.1%
Cavity wall, internal or external insulation10.1%
HeatingHomesShare
Gas boiler73775.7%
Communal heating10811.1%
Electric (storage heaters, panels, boiler)949.7%
Heat pump333.4%
LPG10.1%
Loft / roof insulationHomesShare
No insulation13113.5%
Under 200 mm282.9%
200 mm or more171.7%
Insulated (depth not recorded)727.4%
Flat or other home above71073.0%
Other151.5%
WindowsHomesShare
Single glazed39740.8%
Double glazed35636.6%
Secondary glazing21422.0%
Triple glazed60.6%

Energy rating: B 53 (5.4%) · C 409 (42.0%) · D 374 (38.4%) · E 112 (11.5%) · F 18 (1.8%) · G 7 (0.7%). Houses and bungalows: 6% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 January 1971.

Compared with Kensington and Chelsea and England

Share of homesSloane SquareAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation80.1%79.7%48.7%
Gas boiler75.7%72.9%66.4%
Rated D–G52.5%—56.5%

Caveats

All conservation areas in Kensington and Chelsea · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker