Solar panels, heat pumps and insulation in Chelsea (7767) conservation area

In the Chelsea conservation area (Kensington and Chelsea), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. The area has 32 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 1,122 homes inside the boundary have an energy certificate: 84.2% are solid-wall homes with no wall insulation, 88.1% heat with a gas boiler and 72.5% are rated D–G; 8 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

1,122homes with an energy certificate
84.2%solid walls, no insulation
88.1%heated by a gas boiler
8heat pumps

Article 4: An Article 4 direction published by Kensington and Chelsea covers this area and removes permitted development rights for replacement windows and doors, and other alterations to the house, so there these need planning permission too. (Article 4 - No 100; Article 4 - No 106; Article 4 - No 71)

What needs planning permission in Chelsea

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development)Part 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development)Part 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearancePlanning permission needed (an Article 4 direction here removes this right)Part 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 1,122)

WallsHomesShare
Solid wall (brick or stone), no insulation94584.2%
Cavity wall, unfilled494.4%
Solid wall, internal insulation353.1%
Modern wall (U-value from the design)252.2%
Cavity wall, insulated (as built or unspecified)211.9%
Solid wall, insulated131.2%
Timber frame121.1%
Other or not known100.9%
Cavity wall, partly insulated70.6%
Solid wall, external insulation20.2%
Solid wall, partly insulated20.2%
Cavity wall, filled10.1%
HeatingHomesShare
Gas boiler98888.1%
Communal heating766.8%
Electric (storage heaters, panels, boiler)494.4%
Heat pump80.7%
LPG10.1%
Loft / roof insulationHomesShare
No insulation49744.3%
Under 200 mm958.5%
200 mm or more131.2%
Insulated (depth not recorded)25722.9%
Flat or other home above22219.8%
Other383.4%
WindowsHomesShare
Double glazed69461.9%
Single glazed29926.6%
Secondary glazing12711.3%
Triple glazed20.2%

Energy rating: B 19 (1.7%) · C 290 (25.8%) · D 544 (48.5%) · E 239 (21.3%) · F 24 (2.1%) · G 6 (0.5%). Houses and bungalows: 65% of the homes; solar panels on 0.4% of the certificates. Most common build period on the certificates: before 1900.

Compared with Kensington and Chelsea and England

Share of homesChelseaAll 44 areas in Kensington and ChelseaEngland
Solid walls, no insulation84.2%79.7%48.7%
Gas boiler88.1%72.9%66.4%
Rated D–G72.5%—56.5%

Caveats

All conservation areas in Kensington and Chelsea · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker