Solar panels, heat pumps and insulation in Belsize conservation area

In the Belsize conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 31 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 4,116 homes inside the boundary have an energy certificate: 77.4% are solid-wall homes with no wall insulation, 70.8% heat with a gas boiler and 50.4% are rated D–G; 7 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

4,116homes with an energy certificate
77.4%solid walls, no insulation
70.8%heated by a gas boiler
7heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (13-51 (odd) & 16-60 (even) Belsize Avenue; Basements; Belsize Conservation Area (various properties); Belsize Conservation Area Non-immediate Article 4; Commercial, Business, and Service (Use Class E) to residential (Use Class C3) (outside CAZ))

What needs planning permission in Belsize

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 4,116)

WallsHomesShare
Solid wall (brick or stone), no insulation3,18477.4%
Timber frame2205.3%
Cavity wall, unfilled1894.6%
Cavity wall, insulated (as built or unspecified)1052.6%
Solid wall, internal insulation982.4%
Modern wall (U-value from the design)912.2%
Other or not known521.3%
Cavity wall, partly insulated501.2%
Cavity wall, filled461.1%
Solid wall, partly insulated270.7%
Solid wall, insulated260.6%
Solid wall, external insulation180.4%
Cavity wall, internal or external insulation80.2%
HeatingHomesShare
Gas boiler2,91370.8%
Communal heating85220.7%
Electric (storage heaters, panels, boiler)3418.3%
Heat pump70.2%
LPG20.0%
Solid fuel (wood, coal)10.0%
Loft / roof insulationHomesShare
No insulation56913.8%
Under 200 mm1634.0%
200 mm or more671.6%
Insulated (depth not recorded)3558.6%
Flat or other home above2,88370.1%
Other781.9%
WindowsHomesShare
Double glazed2,38257.9%
Single glazed1,56237.9%
Secondary glazing1664.0%
Triple glazed60.1%

Energy rating: A 2 (0.0%) · B 86 (2.1%) · C 1,955 (47.5%) · D 1,655 (40.2%) · E 375 (9.1%) · F 35 (0.9%) · G 8 (0.2%). Houses and bungalows: 7% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 February 1988.

Compared with Camden and England

Share of homesBelsizeAll 40 areas in CamdenEngland
Solid walls, no insulation77.4%67.1%48.7%
Gas boiler70.8%67.5%66.4%
Rated D–G50.4%—56.5%

Caveats