Solar panels, heat pumps and insulation in Parkhill conservation area

In the Parkhill conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 12 listed buildings; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 779 homes inside the boundary have an energy certificate: 68.3% are solid-wall homes with no wall insulation, 85.9% heat with a gas boiler and 52.6% are rated D–G; 1 has a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

779homes with an energy certificate
68.3%solid walls, no insulation
85.9%heated by a gas boiler
1heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (Basements)

What needs planning permission in Parkhill

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 779)

WallsHomesShare
Solid wall (brick or stone), no insulation53268.3%
Cavity wall, insulated (as built or unspecified)597.6%
Cavity wall, unfilled425.4%
Cavity wall, internal or external insulation395.0%
Cavity wall, filled283.6%
Other or not known212.7%
Timber frame162.1%
Cavity wall, partly insulated121.5%
Modern wall (U-value from the design)81.0%
Solid wall, internal insulation70.9%
Solid wall, partly insulated70.9%
Solid wall, external insulation40.5%
Solid wall, insulated40.5%
HeatingHomesShare
Gas boiler66985.9%
Electric (storage heaters, panels, boiler)8510.9%
Communal heating233.0%
Heat pump10.1%
LPG10.1%
Loft / roof insulationHomesShare
No insulation13116.8%
Under 200 mm486.2%
200 mm or more202.6%
Insulated (depth not recorded)10513.5%
Flat or other home above46659.8%
Other91.2%
WindowsHomesShare
Double glazed51466.0%
Single glazed22228.5%
Secondary glazing415.3%
Triple glazed20.3%

Energy rating: B 19 (2.4%) · C 350 (44.9%) · D 315 (40.4%) · E 80 (10.3%) · F 14 (1.8%) · G 1 (0.1%). Houses and bungalows: 17% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: before 1900. Designated: 1 June 1985.

Compared with Camden and England

Share of homesParkhillAll 40 areas in CamdenEngland
Solid walls, no insulation68.3%67.1%48.7%
Gas boiler85.9%67.5%66.4%
Rated D–G52.6%—56.5%

Caveats

All conservation areas in Camden · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker