EPC Price Check

Solar panels, heat pumps and insulation in Elsworthy conservation area

In the Elsworthy conservation area (Camden), external wall insulation needs planning permission, and so does an air source heat pump on a wall or roof facing the road; one at the back or side, internal and loft insulation and solar panels on a roof slope normally do not. An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. The area has 1 listed building; on a listed building solar panels and heat pumps are not permitted development at all and need planning permission and listed building consent. 292 homes inside the boundary have an energy certificate: 68.8% are solid-wall homes with no wall insulation, 91.8% heat with a gas boiler and 58.2% are rated D–G; 6 have a heat pump. EPC register November 2026; rules as at 21 October 2026.

Data: EPC register November 2026 (latest certificate per home), conservation area boundaries 3 November 2026, permitted development rules as at 21 October 2026 · calculated 5 November 2026 · Methodology and sources

292homes with an energy certificate
68.8%solid walls, no insulation
91.8%heated by a gas boiler
6heat pumps

Article 4: An Article 4 direction published by Camden covers this area, but the published data does not say which rights it removes — check the direction before any work. (Basements)

What needs planning permission in Elsworthy

Work (house, not listed)In a conservation areaRule
Air source heat pump on a wall or roof facing the road, or nearer the road than the housePlanning permission neededPart 14 Class G, G.1(j)
Air source heat pump at the back or side (outdoor unit up to 1.5 m³, MCS Planning Standards, one per house — two on a detached house)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class G
Solar panels on a pitched roof (up to 0.2 m proud, not above the ridge)No permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 14 Class A, A.2(c)
Solar panels on a wall, balcony or roof enclosure facing the roadPlanning permission neededPart 14 Class A, A.2(e)
Solar panels on a flat roof (up to 0.6 m above the roof)Prior approval of appearance from the council, unless an Article 4 direction removes it — check with the councilPart 14 Class A, condition A(ba)
External wall insulation (render, cladding, timber, tiles)Planning permission neededPart 1 Class A, A.2(a)
Internal wall insulation, loft insulation, cavity wall insulationNot development: no planning permission—
Replacement windows and doors of similar appearanceNo permission needed (permitted development), unless an Article 4 direction removes it — check with the councilPart 1 Class A, A.3(a)

The homes in the area (latest certificate per home, n = 292)

WallsHomesShare
Solid wall (brick or stone), no insulation20168.8%
Timber frame237.9%
Cavity wall, insulated (as built or unspecified)227.5%
Solid wall, internal insulation175.8%
Modern wall (U-value from the design)113.8%
Cavity wall, unfilled72.4%
Cavity wall, partly insulated41.4%
Solid wall, insulated41.4%
Other or not known20.7%
Solid wall, partly insulated10.3%
HeatingHomesShare
Gas boiler26891.8%
Communal heating113.8%
Electric (storage heaters, panels, boiler)62.1%
Heat pump62.1%
LPG10.3%
Loft / roof insulationHomesShare
No insulation6321.6%
Under 200 mm196.5%
200 mm or more93.1%
Insulated (depth not recorded)4515.4%
Flat or other home above14549.7%
Other113.8%
WindowsHomesShare
Double glazed17961.3%
Single glazed10234.9%
Secondary glazing82.7%
Triple glazed31.0%

Energy rating: B 19 (6.5%) · C 103 (35.3%) · D 122 (41.8%) · E 41 (14.0%) · F 7 (2.4%). Houses and bungalows: 23% of the homes; solar panels on 0.0% of the certificates. Most common build period on the certificates: 1900-1929. Designated: 1 November 1985.

Compared with Camden and England

Share of homesElsworthyAll 40 areas in CamdenEngland
Solid walls, no insulation68.8%67.1%48.7%
Gas boiler91.8%67.5%66.4%
Rated D–G58.2%—56.5%

Caveats

All conservation areas in Camden · The rules for every conservation area

Guides: Heat pumps · Solar panels · External wall insulation · Replacement windows · Am I in a conservation area? Postcode checker