Does a C-or-better EPC sell for more in YO8 6 (North Yorkshire)?

No measurable EPC premium here. In postcode sector YO8 6 (North Yorkshire), comparing like with like — same floor area, property type, build period and year of sale — the difference is +3.6% (95% range −0.3% to +7.6%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 4% more per square metre than D–G homes (median £2,317 vs £2,237, 892 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.6%like-for-like: no measurable difference (95% range −0.3% to +7.6%)
+4%raw gap per m² (before like-for-like)
892sales matched to a certificate
60%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 130 m² against 104 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 84% of C+ and 89% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+4%—
Whole price, nothing held equal+19.8%+12.3% to +27.9%
Same floor area+5.9%+2.4% to +9.4%
+ same property type+7.2%+3.9% to +10.6%
+ same build period+8.5%+4.0% to +13.2%
+ same year of sale+3.6%−0.3% to +7.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in YO8 6

EPC band (last certificate before sale)SalesMedian £ per m²
A4too few
B57£2,468
C270£2,283
D344£2,260
E159£2,241
F50£2,158
G8too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached210£2,302309£2,284
Semi-detached67£2,438190£2,204
Terraced50£2,14159£2,132
Flat / maisonette4—3—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector YO8 6892+3.6%−0.3% to +7.6%
District YO89,768−1.1%−2.3% to 0.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in YO8 6 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)52 (988 meters)
Median gas use per meter (median of postcodes)11,539 kWh
Gas-heated homes with an EPC691
Energy implied by their certificates (median)18,640 kWh
Metered gas as a share of the certificate figure (median of 49 postcodes)60% (middle half 52%–66%)

Certificates by band imply: B 11,225 kWh (48 homes) · C 16,142 kWh (317 homes) · D 20,803 kWh (264 homes) · E 33,738 kWh (53 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in YO8 6?

About 640 of the 690 gas-heated homes with an energy certificate in YO8 6 (93%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 1 of the 51 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector51
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 10,290 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,050
Gas-heated homes with an EPC on these substations690
Of them, could switch within the spare capacity≈ 640 (93%)
…if each heat pump adds 3 kW (a cold snap)≈ 610 (88%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

892 of 996 house and flat sales in the sector since 2015 (90%) were matched to a certificate.

How this is calculated

Caveats