EPC Price Check

Does a C-or-better EPC sell for more in YO32 2 (York)?

A small premium for a better EPC here. In postcode sector YO32 2 (York), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 2.7% more (95% range +0.7% to +4.7%). The raw gap is bigger: C+ homes sold for 5% less per square metre than D–G homes (median £3,320 vs £3,495, 1,069 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+2.7% ▲like-for-like: small premium (95% range +0.7% to +4.7%)
−5%raw gap per m² (before like-for-like)
1,069sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 61 m² against 73 m² for D–G; the most common build period is 1976–1982 for C+ and 1967–1975 for D–G; 55% of C+ and 82% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−5%—
Whole price, nothing held equal−12.5%−16.7% to −8.1%
Same floor area−4.6%−7.2% to −2.0%
+ same property type+3.5%+1.2% to +5.9%
+ same build period+3.9%+1.5% to +6.5%
+ same year of sale+2.7%+0.7% to +4.7%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in YO32 2

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B37£3,100
C382£3,333
D537£3,623
E100£3,155
F11£3,240

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached111£3,676289£3,657
Semi-detached121£3,750241£3,598
Terraced60£3,19764£3,384
Flat / maisonette129£2,83354£3,111

Compared with the wider area

AreaSalesLike-for-like95% range
Sector YO32 21,069+2.7%+0.7% to +4.7%
District YO324,531+1.9%+0.9% to +3.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in YO32 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)113 (2,207 meters)
Median gas use per meter (median of postcodes)10,924 kWh
Gas-heated homes with an EPC1,345
Energy implied by their certificates (median)16,378 kWh
Metered gas as a share of the certificate figure (median of 109 postcodes)61% (middle half 55%–68%)

Certificates by band imply: B 10,465 kWh (32 homes) · C 13,225 kWh (490 homes) · D 17,873 kWh (731 homes) · E 26,276 kWh (80 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in YO32 2?

About 1,340 of the 1,343 gas-heated homes with an energy certificate in YO32 2 (100%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 1 of the 27 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector27
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 7,530 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,430
Gas-heated homes with an EPC on these substations1,343
Of them, could switch within the spare capacity≈ 1,340 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,110 (83%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

1,069 of 1,110 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats