EPC Price Check

Does a C-or-better EPC sell for more in YO31 1 (York)?

A small premium for a better EPC here. In postcode sector YO31 1 (York), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 3.7% more (95% range +0.9% to +6.6%). The raw gap is different: C+ homes sold for 1% less per square metre than D–G homes (median £3,548 vs £3,578, 839 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.7% ▲like-for-like: small premium (95% range +0.9% to +6.6%)
−1%raw gap per m² (before like-for-like)
839sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 114 m² against 89 m² for D–G; both groups are most often built in 1950–1966; 86% of C+ and 87% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−1%—
Whole price, nothing held equal+22.5%+14.2% to +31.5%
Same floor area+1.1%−2.6% to +4.9%
+ same property type+3.4%+0.1% to +6.9%
+ same build period+4.4%+0.8% to +8.2%
+ same year of sale+3.7%+0.9% to +6.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in YO31 1

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B22£3,605
C179£3,516
D489£3,647
E128£3,438
F14£3,287
G5too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached68£3,552185£3,866
Semi-detached106£3,671369£3,585
Terraced16£3,42063£3,333
Flat / maisonette13£2,47019£2,990

Compared with the wider area

AreaSalesLike-for-like95% range
Sector YO31 1839+3.7%+0.9% to +6.6%
District YO315,182−2.1%−3.3% to −0.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in YO31 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)103 (1,945 meters)
Median gas use per meter (median of postcodes)13,042 kWh
Gas-heated homes with an EPC1,208
Energy implied by their certificates (median)21,132 kWh
Metered gas as a share of the certificate figure (median of 101 postcodes)61% (middle half 55%–65%)

Certificates by band imply: B 11,523 kWh (40 homes) · C 17,690 kWh (320 homes) · D 21,250 kWh (661 homes) · E 32,535 kWh (171 homes) · F 50,855 kWh (11 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in YO31 1?

Yes, on Northern Powergrid's figures: the local substations serving YO31 1 have enough spare capacity for all 883 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 9 local substations would fill up first.

Local (street) substations serving homes in the sector9
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 3,520 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,070
Gas-heated homes with an EPC on these substations883 (73% of the sector's)
Of them, could switch within the spare capacity≈ 880 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 780 (88%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

839 of 875 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats