EPC Price Check

Does a C-or-better EPC sell for more in WF9 5 (Wakefield)?

A small premium for a better EPC here. In postcode sector WF9 5 (Wakefield), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 5.8% more (95% range +0.6% to +11.3%). The raw gap is bigger: C+ homes sold for 14% more per square metre than D–G homes (median £1,635 vs £1,438, 841 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+5.8% ▲like-for-like: small premium (95% range +0.6% to +11.3%)
+14%raw gap per m² (before like-for-like)
841sales matched to a certificate
66%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 77 m² against 80 m² for D–G; the most common build period is 2012 onwards for C+ and 1930–1949 for D–G; 80% of C+ and 73% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+14%—
Whole price, nothing held equal+13.8%+7.1% to +20.9%
Same floor area+13.4%+7.3% to +19.7%
+ same property type+15.2%+10.1% to +20.6%
+ same build period+13.9%+6.5% to +21.8%
+ same year of sale+5.8%+0.6% to +11.3%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in WF9 5

EPC band (last certificate before sale)SalesMedian £ per m²
B375£1,646
C133£1,626
D247£1,514
E73£1,271
F11£938
G2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached69£1,86975£2,228
Semi-detached338£1,688167£1,529
Terraced96£1,41986£1,035
Flat / maisonette5—5—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WF9 5841+5.8%+0.6% to +11.3%
District WF96,180+0.4%−1.3% to +2.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WF9 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)127 (2,231 meters)
Median gas use per meter (median of postcodes)9,593 kWh
Gas-heated homes with an EPC1,786
Energy implied by their certificates (median)14,081 kWh
Metered gas as a share of the certificate figure (median of 123 postcodes)66% (middle half 56%–74%)

Certificates by band imply: B 6,469 kWh (353 homes) · C 12,881 kWh (551 homes) · D 17,741 kWh (788 homes) · E 27,698 kWh (80 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WF9 5?

About 1,410 of the 1,717 gas-heated homes with an energy certificate in WF9 5 (82%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 8 of the 18 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector18
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 6,420 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 3,770
Gas-heated homes with an EPC on these substations1,717 (96% of the sector's)
Of them, could switch within the spare capacity≈ 1,410 (82%)
…if each heat pump adds 3 kW (a cold snap)≈ 990 (58%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

841 of 895 house and flat sales in the sector since 2015 (94%) were matched to a certificate.

How this is calculated

Caveats