Does a C-or-better EPC sell for more in WF16 9 (Kirklees)?

A small premium for a better EPC here. In postcode sector WF16 9 (Kirklees), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 3.9% more (95% range +0.3% to +7.5%). The raw gap is bigger: C+ homes sold for 12% more per square metre than D–G homes (median £1,879 vs £1,682, 997 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.9% ▲like-for-like: small premium (95% range +0.3% to +7.5%)
+12%raw gap per m² (before like-for-like)
997sales matched to a certificate
63%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 80 m² against 74 m² for D–G; the most common build period is 2007–2011 for C+ and 1930–1949 for D–G; 61% of C+ and 70% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+12%—
Whole price, nothing held equal+21.0%+14.6% to +27.8%
Same floor area+13.8%+8.9% to +18.9%
+ same property type+22.2%+17.7% to +26.9%
+ same build period+10.2%+5.5% to +15.0%
+ same year of sale+3.9%+0.3% to +7.5%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in WF16 9

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B25£1,807
C314£1,882
D460£1,803
E148£1,400
F30£1,373
G19£1,167

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached47£2,077114£2,020
Semi-detached161£1,935348£1,736
Terraced113£1,768187£1,328
Flat / maisonette19£1,0088—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WF16 9997+3.9%+0.3% to +7.5%
District WF161,631+4.1%+1.2% to +7.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WF16 9 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)163 (3,009 meters)
Median gas use per meter (median of postcodes)10,681 kWh
Gas-heated homes with an EPC2,111
Energy implied by their certificates (median)16,067 kWh
Metered gas as a share of the certificate figure (median of 159 postcodes)63% (middle half 53%–73%)

Certificates by band imply: B 7,853 kWh (73 homes) · C 12,098 kWh (765 homes) · D 17,548 kWh (947 homes) · E 29,301 kWh (278 homes) · F 40,382 kWh (39 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WF16 9?

About 1,330 of the 1,568 gas-heated homes with an energy certificate in WF16 9 (85%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 2 of the 26 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector26
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 9,170 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,390
Gas-heated homes with an EPC on these substations1,568 (74% of the sector's)
Of them, could switch within the spare capacity≈ 1,330 (85%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,200 (77%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

997 of 1,073 house and flat sales in the sector since 2015 (93%) were matched to a certificate.

How this is calculated

Caveats