EPC Price Check

Does a C-or-better EPC sell for more in WF1 1 (Wakefield)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector WF1 1 (Wakefield), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district WF1 as a whole the like-for-like difference is +1.2% (95% range −0.8% to +3.2%). The raw gap is different: C+ homes sold for 9% less per square metre than D–G homes (median £1,353 vs £1,481, 107 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+1.2%like-for-like in district WF1 (95% range −0.8% to +3.2%); too few sales in this sector
−9%raw gap per m² (before like-for-like)
107sales matched to a certificate
72%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 61 m² against 63 m² for D–G; the most common build period is 2007–2011 for C+ and 2012 onwards for D–G.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in WF1 1

EPC band (last certificate before sale)SalesMedian £ per m²
B21£1,389
C44£1,269
D33£1,597
E8too few
F1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Terraced4—9—
Flat / maisonette61£1,33833£1,522

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WF1 1107too few—
District WF16,547+1.2%−0.8% to +3.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WF1 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)20 (243 meters)
Median gas use per meter (median of postcodes)10,634 kWh
Gas-heated homes with an EPC176
Energy implied by their certificates (median)11,990 kWh
Metered gas as a share of the certificate figure (median of 15 postcodes)72% (middle half 57%–102%)

Certificates by band imply: B 5,900 kWh (11 homes) · C 8,434 kWh (90 homes) · D 19,407 kWh (53 homes) · E 29,498 kWh (20 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WF1 1?

Yes, on Northern Powergrid's figures: the local substations serving WF1 1 have enough spare capacity for all 136 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 46 local substations would fill up first.

Local (street) substations serving homes in the sector46
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 25,960 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 15,270
Gas-heated homes with an EPC on these substations136 (77% of the sector's)
Of them, could switch within the spare capacity≈ 136 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 136 (100%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

107 of 183 house and flat sales in the sector since 2015 (58%) were matched to a certificate.

How this is calculated

Caveats