Does a C-or-better EPC sell for more in WC1N 2 (Camden)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector WC1N 2 (Camden), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district WC1N as a whole the like-for-like difference is −0.4% (95% range −5.6% to +5.0%). The raw gap is different: C+ homes sold for 3% more per square metre than D–G homes (median £13,568 vs £13,229, 79 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−0.4%like-for-like in district WC1N (95% range −5.6% to +5.0%); too few sales in this sector
+3%raw gap per m² (before like-for-like)
79sales matched to a certificate
64%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 76 m² against 105 m² for D–G; both groups are most often built before 1900; 0% of C+ and 7% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in WC1N 2

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B3too few
C46£13,072
D24£13,425
E3too few
F2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Semi-detached0—2—
Terraced9—9—
Flat / maisonette41£13,65918£13,145

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WC1N 279too few—
District WC1N304−0.4%−5.6% to +5.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WC1N 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)24 (312 meters)
Median gas use per meter (median of postcodes)8,449 kWh
Gas-heated homes with an EPC282
Energy implied by their certificates (median)12,450 kWh
Metered gas as a share of the certificate figure (median of 23 postcodes)64% (middle half 53%–74%)

Certificates by band imply: B 5,915 kWh (22 homes) · C 9,572 kWh (154 homes) · D 17,395 kWh (89 homes) · E 29,448 kWh (13 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WC1N 2?

About 260 of the 274 gas-heated homes with an energy certificate in WC1N 2 (96%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 2 of the 20 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector20
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 7,700 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,530
Gas-heated homes with an EPC on these substations274 (97% of the sector's)
Of them, could switch within the spare capacity≈ 260 (96%)
…if each heat pump adds 3 kW (a cold snap)≈ 250 (90%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

79 of 105 house and flat sales in the sector since 2015 (75%) were matched to a certificate.

How this is calculated

Caveats