EPC Price Check

Does a C-or-better EPC sell for more in WC1B 3 (Camden)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector WC1B 3 (Camden), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure. The raw gap is bigger: C+ homes sold for 27% more per square metre than D–G homes (median £15,549 vs £12,228, 49 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+27%raw gap per m² (before like-for-like)
49sales matched to a certificate
42%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 109 m² against 98 m² for D–G; both groups are most often built before 1900.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown.

Sold prices by EPC band in WC1B 3

EPC band (last certificate before sale)SalesMedian £ per m²
B1too few
C13£15,657
D20£12,275
E14£12,163
G1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Flat / maisonette14£15,54935£12,228

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WC1B 349too few—
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WC1B 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)16 (191 meters)
Median gas use per meter (median of postcodes)8,851 kWh
Gas-heated homes with an EPC155
Energy implied by their certificates (median)16,991 kWh
Metered gas as a share of the certificate figure (median of 13 postcodes)42% (middle half 39%–64%)

Certificates by band imply: C 12,735 kWh (72 homes) · D 21,200 kWh (67 homes) · E 29,048 kWh (13 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WC1B 3?

Yes, on UK Power Networks' figures: the local substations serving WC1B 3 have enough spare capacity for all 153 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 22 local substations would fill up first.

Local (street) substations serving homes in the sector22
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 8,480 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,990
Gas-heated homes with an EPC on these substations153 (99% of the sector's)
Of them, could switch within the spare capacity≈ 150 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 150 (100%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

49 of 65 house and flat sales in the sector since 2015 (75%) were matched to a certificate.

How this is calculated

Caveats