EPC Price Check

Does a C-or-better EPC sell for more in WA3 5 (Warrington)?

A small premium for a better EPC here. In postcode sector WA3 5 (Warrington), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.3% more (95% range +1.0% to +7.7%). The raw gap is bigger: C+ homes sold for 14% more per square metre than D–G homes (median £2,770 vs £2,428, 880 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.3% ▲like-for-like: small premium (95% range +1.0% to +7.7%)
+14%raw gap per m² (before like-for-like)
880sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 86 m² against 86 m² for D–G; the most common build period is 2012 onwards for C+ and 1950–1966 for D–G; 76% of C+ and 77% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+14%—
Whole price, nothing held equal+19.5%+12.8% to +26.6%
Same floor area+14.2%+9.9% to +18.6%
+ same property type+13.7%+9.9% to +17.7%
+ same build period+10.8%+6.5% to +15.3%
+ same year of sale+4.3%+1.0% to +7.7%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in WA3 5

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B98£2,850
C248£2,738
D407£2,464
E108£2,406
F12£2,217
G5too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached102£2,93086£2,713
Semi-detached162£2,772325£2,500
Terraced52£2,61495£2,222
Flat / maisonette32£2,17726£1,955

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WA3 5880+4.3%+1.0% to +7.7%
District WA38,697+1.4%−0.3% to +3.1%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WA3 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)111 (1,892 meters)
Median gas use per meter (median of postcodes)10,652 kWh
Gas-heated homes with an EPC1,352
Energy implied by their certificates (median)16,985 kWh
Metered gas as a share of the certificate figure (median of 110 postcodes)61% (middle half 51%–67%)

Certificates by band imply: A 5,389 kWh (20 homes) · B 7,007 kWh (102 homes) · C 13,809 kWh (450 homes) · D 18,950 kWh (629 homes) · E 29,593 kWh (141 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WA3 5?

About 1,340 of the 1,352 gas-heated homes with an energy certificate in WA3 5 (99%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 3 of the 44 local substations would fill up before every gas-heated home they supply could switch; 1 is already at or over capacity.

Local (street) substations serving homes in the sector44
Already at or over capacity1 (2%)
Their combined spare capacity (demand headroom)≈ 8,910 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,240
Gas-heated homes with an EPC on these substations1,352
Of them, could switch within the spare capacity≈ 1,340 (99%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,190 (88%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

880 of 920 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats