EPC Price Check

Does a C-or-better EPC sell for more in WA14 2 (Trafford)?

A small premium for a better EPC here. In postcode sector WA14 2 (Trafford), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 5.2% more (95% range +0.5% to +10.0%). The raw gap is different: C+ homes sold for 0% less per square metre than D–G homes (median £4,112 vs £4,121, 1,246 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+5.2% ▲like-for-like: small premium (95% range +0.5% to +10.0%)
0%raw gap per m² (before like-for-like)
1,246sales matched to a certificate
59%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 94 m² against 130 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 11% of C+ and 34% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)0%—
Whole price, nothing held equal−28.4%−33.9% to −22.4%
Same floor area+2.1%−1.6% to +5.8%
+ same property type+10.3%+6.0% to +14.7%
+ same build period+9.0%+4.0% to +14.2%
+ same year of sale+5.2%+0.5% to +10.0%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in WA14 2

EPC band (last certificate before sale)SalesMedian £ per m²
B128£5,139
C364£3,842
D430£4,232
E265£4,000
F51£3,846
G8too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached39£4,928106£4,764
Semi-detached15£4,528151£4,284
Terraced67£4,899314£4,131
Flat / maisonette371£3,722183£3,485

Compared with the wider area

AreaSalesLike-for-like95% range
Sector WA14 21,246+5.2%+0.5% to +10.0%
District WA146,025−0.7%−2.4% to +1.1%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in WA14 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)156 (2,293 meters)
Median gas use per meter (median of postcodes)16,456 kWh
Gas-heated homes with an EPC1,838
Energy implied by their certificates (median)22,092 kWh
Metered gas as a share of the certificate figure (median of 145 postcodes)59% (middle half 49%–68%)

Certificates by band imply: B 8,602 kWh (141 homes) · C 13,184 kWh (637 homes) · D 25,925 kWh (659 homes) · E 48,608 kWh (328 homes) · F 95,669 kWh (71 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in WA14 2?

About 1,730 of the 1,838 gas-heated homes with an energy certificate in WA14 2 (94%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 5 of the 30 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector30
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 12,690 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 7,470
Gas-heated homes with an EPC on these substations1,838
Of them, could switch within the spare capacity≈ 1,730 (94%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,540 (84%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,246 of 1,484 house and flat sales in the sector since 2015 (84%) were matched to a certificate.

How this is calculated

Caveats