EPC Price Check

Does a C-or-better EPC sell for more in W1K 2 (Westminster)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector W1K 2 (Westminster), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district W1K as a whole the like-for-like difference is +4.9% (95% range −8.5% to +20.3%). The raw gap is bigger: C+ homes sold for 8% more per square metre than D–G homes (median £27,503 vs £25,419, 80 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.9%like-for-like in district W1K (95% range −8.5% to +20.3%); too few sales in this sector
+8%raw gap per m² (before like-for-like)
80sales matched to a certificate
55%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 122 m² against 138 m² for D–G; both groups are most often built before 1900; 4% of C+ and 0% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in W1K 2

EPC band (last certificate before sale)SalesMedian £ per m²
B1too few
C25£27,253
D25£28,704
E19£24,390
F7too few
G3too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Semi-detached1—0—
Terraced3—11£22,639
Flat / maisonette22£27,99043£28,261

Compared with the wider area

AreaSalesLike-for-like95% range
Sector W1K 280too few—
District W1K311+4.9%−8.5% to +20.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in W1K 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)13 (83 meters)
Median gas use per meter (median of postcodes)9,169 kWh
Gas-heated homes with an EPC242
Energy implied by their certificates (median)27,912 kWh
Metered gas as a share of the certificate figure (median of 9 postcodes)55% (middle half 54%–74%)

Certificates by band imply: C 15,430 kWh (70 homes) · D 30,927 kWh (92 homes) · E 46,110 kWh (61 homes) · F 87,000 kWh (11 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in W1K 2?

About 230 of the 237 gas-heated homes with an energy certificate in W1K 2 (96%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 1 of the 28 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector28
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 10,560 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,210
Gas-heated homes with an EPC on these substations237 (98% of the sector's)
Of them, could switch within the spare capacity≈ 230 (96%)
…if each heat pump adds 3 kW (a cold snap)≈ 230 (96%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

80 of 106 house and flat sales in the sector since 2015 (75%) were matched to a certificate.

How this is calculated

Caveats