EPC Price Check

Does a C-or-better EPC sell for more in TS6 6 (Redcar and Cleveland)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector TS6 6 (Redcar and Cleveland), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district TS6 as a whole the like-for-like difference is −4.0% (95% range −6.6% to −1.3%). The raw gap is bigger: C+ homes sold for 85% more per square metre than D–G homes (median £952 vs £515, 269 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−4.0%like-for-like in district TS6 (95% range −6.6% to −1.3%); too few sales in this sector
+85%raw gap per m² (before like-for-like)
269sales matched to a certificate
54%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 76 m² against 77 m² for D–G; the most common build period is 1950–1966 for C+ and 1900–1929 for D–G; 52% of C+ and 38% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in TS6 6

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B4too few
C38£952
D151£613
E51£424
F9too few
G14£463

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached0—3—
Semi-detached23£1,05383£906
Terraced20£717138£422
Flat / maisonette1—1—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector TS6 6269too few—
District TS64,037−4.0%−6.6% to −1.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in TS6 6 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)73 (1,346 meters)
Median gas use per meter (median of postcodes)8,674 kWh
Gas-heated homes with an EPC1,095
Energy implied by their certificates (median)14,910 kWh
Metered gas as a share of the certificate figure (median of 68 postcodes)54% (middle half 46%–66%)

Certificates by band imply: B 5,408 kWh (51 homes) · C 12,090 kWh (479 homes) · D 17,947 kWh (453 homes) · E 27,257 kWh (99 homes) · F 46,160 kWh (12 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in TS6 6?

About 960 of the 1,069 gas-heated homes with an energy certificate in TS6 6 (90%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 2 of the 23 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector23
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 9,660 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,680
Gas-heated homes with an EPC on these substations1,069 (98% of the sector's)
Of them, could switch within the spare capacity≈ 960 (90%)
…if each heat pump adds 3 kW (a cold snap)≈ 810 (76%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

269 of 279 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats