Does a C-or-better EPC sell for more in TS25 1 (Hartlepool)?

A small premium for a better EPC here. In postcode sector TS25 1 (Hartlepool), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.0% more (95% range +0.1% to +8.0%). The raw gap is bigger: C+ homes sold for 21% more per square metre than D–G homes (median £1,704 vs £1,410, 1,170 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.0% ▲like-for-like: small premium (95% range +0.1% to +8.0%)
+21%raw gap per m² (before like-for-like)
1,170sales matched to a certificate
59%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 91 m² against 87 m² for D–G; the most common build period is 1996–2002 for C+ and 1930–1949 for D–G; 76% of C+ and 63% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+21%—
Whole price, nothing held equal+28.5%+21.7% to +35.8%
Same floor area+27.6%+22.1% to +33.4%
+ same property type+16.9%+13.1% to +20.9%
+ same build period+11.4%+7.0% to +16.1%
+ same year of sale+4.0%+0.1% to +8.0%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in TS25 1

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B98£1,649
C391£1,708
D535£1,529
E119£1,068
F21£1,343
G5too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached183£1,900176£1,854
Semi-detached191£1,667250£1,542
Terraced97£1,422241£933
Flat / maisonette19£1,18613£980

Compared with the wider area

AreaSalesLike-for-like95% range
Sector TS25 11,170+4.0%+0.1% to +8.0%
District TS255,463+1.5%−0.3% to +3.4%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in TS25 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)191 (4,001 meters)
Median gas use per meter (median of postcodes)9,866 kWh
Gas-heated homes with an EPC2,938
Energy implied by their certificates (median)15,332 kWh
Metered gas as a share of the certificate figure (median of 180 postcodes)59% (middle half 48%–68%)

Certificates by band imply: A 4,499 kWh (45 homes) · B 6,595 kWh (336 homes) · C 12,947 kWh (1,197 homes) · D 19,298 kWh (1,086 homes) · E 30,568 kWh (245 homes) · F 47,204 kWh (27 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in TS25 1?

About 1,790 of the 2,263 gas-heated homes with an energy certificate in TS25 1 (79%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 9 of the 37 local substations would fill up before every gas-heated home they supply could switch; 1 is already at or over capacity.

Local (street) substations serving homes in the sector37
Already at or over capacity1 (3%)
Their combined spare capacity (demand headroom)≈ 11,970 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 7,040
Gas-heated homes with an EPC on these substations2,263 (77% of the sector's)
Of them, could switch within the spare capacity≈ 1,790 (79%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,310 (58%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

1,170 of 1,213 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats