EPC Price Check

Does a C-or-better EPC sell for more in TS24 8 (Hartlepool)?

No measurable EPC premium here. In postcode sector TS24 8 (Hartlepool), comparing like with like — same floor area, property type, build period and year of sale — the difference is +1.0% (95% range −5.5% to +8.1%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 44% more per square metre than D–G homes (median £1,146 vs £796, 646 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+1.0%like-for-like: no measurable difference (95% range −5.5% to +8.1%)
+44%raw gap per m² (before like-for-like)
646sales matched to a certificate
56%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 78 m² against 76 m² for D–G; the most common build period is 2007–2011 for C+ and 1900–1929 for D–G; 37% of C+ and 26% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+44%—
Whole price, nothing held equal+47.5%+38.1% to +57.6%
Same floor area+48.4%+39.5% to +57.9%
+ same property type+41.7%+33.7% to +50.2%
+ same build period+7.1%−0.5% to +15.4%
+ same year of sale+1.0%−5.5% to +8.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in TS24 8

EPC band (last certificate before sale)SalesMedian £ per m²
B50£1,054
C222£1,192
D256£847
E104£595
F7too few
G7too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached13£1,3551—
Semi-detached88£1,24798£1,072
Terraced153£1,097263£652
Flat / maisonette18£1,09712£1,020

Compared with the wider area

AreaSalesLike-for-like95% range
Sector TS24 8646+1.0%−5.5% to +8.1%
District TS242,616+4.1%+0.2% to +8.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in TS24 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)136 (2,923 meters)
Median gas use per meter (median of postcodes)8,146 kWh
Gas-heated homes with an EPC2,569
Energy implied by their certificates (median)14,628 kWh
Metered gas as a share of the certificate figure (median of 135 postcodes)56% (middle half 49%–67%)

Certificates by band imply: B 6,558 kWh (276 homes) · C 12,516 kWh (1,108 homes) · D 17,832 kWh (985 homes) · E 27,942 kWh (174 homes) · F 38,223 kWh (22 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in TS24 8?

About 1,770 of the 2,064 gas-heated homes with an energy certificate in TS24 8 (86%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 5 of the 17 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector17
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 8,020 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,720
Gas-heated homes with an EPC on these substations2,064 (80% of the sector's)
Of them, could switch within the spare capacity≈ 1,770 (86%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,300 (63%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

646 of 677 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats