EPC Price Check

Does a C-or-better EPC sell for more in TS13 5 (North Yorkshire)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector TS13 5 (North Yorkshire), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district TS13 as a whole the like-for-like difference is −10.6% (95% range −17.0% to −3.8%). The raw gap is bigger: C+ homes sold for 14% less per square metre than D–G homes (median £2,018 vs £2,340, 370 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−10.6%like-for-like in district TS13 (95% range −17.0% to −3.8%); too few sales in this sector
−14%raw gap per m² (before like-for-like)
370sales matched to a certificate
56%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 102 m² against 84 m² for D–G; both groups are most often built before 1900; 66% of C+ and 48% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in TS13 5

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B5too few
C29£1,986
D120£2,098
E94£2,272
F86£2,523
G35£2,687

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached10£2,52062£2,556
Semi-detached13£1,945100£2,047
Terraced11£1,545160£2,393
Flat / maisonette1—13£2,563

Compared with the wider area

AreaSalesLike-for-like95% range
Sector TS13 5370too few—
District TS131,463−10.6%−17.0% to −3.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in TS13 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)35 (569 meters)
Median gas use per meter (median of postcodes)9,713 kWh
Gas-heated homes with an EPC381
Energy implied by their certificates (median)17,075 kWh
Metered gas as a share of the certificate figure (median of 35 postcodes)56% (middle half 47%–72%)

Certificates by band imply: B 6,372 kWh (22 homes) · C 14,092 kWh (136 homes) · D 19,368 kWh (173 homes) · E 31,196 kWh (44 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in TS13 5?

Yes, on Northern Powergrid's figures: the local substations serving TS13 5 have enough spare capacity for all 354 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 21 local substations would fill up first.

Local (street) substations serving homes in the sector21
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 4,340 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,550
Gas-heated homes with an EPC on these substations354 (93% of the sector's)
Of them, could switch within the spare capacity≈ 350 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 350 (100%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

370 of 447 house and flat sales in the sector since 2015 (83%) were matched to a certificate.

How this is calculated

Caveats