Does a C-or-better EPC sell for more in TN10 3 (Tonbridge and Malling)?

A small premium for a better EPC here. In postcode sector TN10 3 (Tonbridge and Malling), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 3.6% more (95% range +0.8% to +6.6%). The raw gap is bigger: C+ homes sold for 5% more per square metre than D–G homes (median £4,426 vs £4,218, 956 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.6% ▲like-for-like: small premium (95% range +0.8% to +6.6%)
+5%raw gap per m² (before like-for-like)
956sales matched to a certificate
60%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 92 m² against 88 m² for D–G; the most common build period is 1967–1975 for C+ and 1950–1966 for D–G; 50% of C+ and 72% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+5%—
Whole price, nothing held equal+4.4%−1.5% to +10.6%
Same floor area+2.7%−0.9% to +6.5%
+ same property type+6.7%+3.3% to +10.3%
+ same build period+6.1%+2.8% to +9.6%
+ same year of sale+3.6%+0.8% to +6.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in TN10 3

EPC band (last certificate before sale)SalesMedian £ per m²
B69£5,208
C231£4,294
D505£4,286
E125£4,127
F19£3,678
G7too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached63£4,617126£4,949
Semi-detached86£4,417349£4,250
Terraced77£3,721138£3,650
Flat / maisonette74£5,19943£3,936

Compared with the wider area

AreaSalesLike-for-like95% range
Sector TN10 3956+3.6%+0.8% to +6.6%
District TN102,063+3.2%+1.3% to +5.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in TN10 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)178 (3,264 meters)
Median gas use per meter (median of postcodes)10,674 kWh
Gas-heated homes with an EPC1,985
Energy implied by their certificates (median)16,697 kWh
Metered gas as a share of the certificate figure (median of 170 postcodes)60% (middle half 53%–70%)

Certificates by band imply: B 5,660 kWh (131 homes) · C 12,401 kWh (699 homes) · D 18,770 kWh (936 homes) · E 27,905 kWh (203 homes) · F 47,506 kWh (13 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in TN10 3?

About 1,600 of the 1,934 gas-heated homes with an energy certificate in TN10 3 (83%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 10 of the 27 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector27
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 4,850 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,850
Gas-heated homes with an EPC on these substations1,934 (97% of the sector's)
Of them, could switch within the spare capacity≈ 1,600 (83%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,210 (62%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

956 of 1,005 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats