EPC Price Check

Does a C-or-better EPC sell for more in SR5 2 (Sunderland)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector SR5 2 (Sunderland), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district SR5 as a whole the like-for-like difference is +1.8% (95% range −1.0% to +4.8%). The raw gap is bigger: C+ homes sold for 45% more per square metre than D–G homes (median £1,165 vs £803, 421 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+1.8%like-for-like in district SR5 (95% range −1.0% to +4.8%); too few sales in this sector
+45%raw gap per m² (before like-for-like)
421sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 67 m² against 82 m² for D–G; the most common build period is 2012 onwards for C+ and 1900–1929 for D–G; 31% of C+ and 13% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in SR5 2

EPC band (last certificate before sale)SalesMedian £ per m²
B44£1,474
C88£1,019
D176£843
E92£745
F15£570
G6too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached6—0—
Semi-detached35£1,47339£1,036
Terraced38£1,034234£783
Flat / maisonette53£95216£535

Compared with the wider area

AreaSalesLike-for-like95% range
Sector SR5 2421too few—
District SR52,970+1.8%−1.0% to +4.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in SR5 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)127 (2,485 meters)
Median gas use per meter (median of postcodes)8,996 kWh
Gas-heated homes with an EPC2,072
Energy implied by their certificates (median)14,049 kWh
Metered gas as a share of the certificate figure (median of 122 postcodes)61% (middle half 48%–73%)

Certificates by band imply: B 6,658 kWh (201 homes) · C 11,116 kWh (857 homes) · D 17,283 kWh (755 homes) · E 28,919 kWh (234 homes) · F 41,973 kWh (23 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in SR5 2?

About 1,380 of the 1,713 gas-heated homes with an energy certificate in SR5 2 (81%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 4 of the 20 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector20
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 9,320 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,480
Gas-heated homes with an EPC on these substations1,713 (83% of the sector's)
Of them, could switch within the spare capacity≈ 1,380 (81%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,110 (65%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

421 of 440 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats