EPC Price Check

Does a C-or-better EPC sell for more in SK23 9 (High Peak)?

No premium here: C+ homes sold for slightly less. In postcode sector SK23 9 (High Peak), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 7.4% less (95% range −12.1% to −2.5%). The raw gap is different: C+ homes sold for 3% more per square metre than D–G homes (median £2,680 vs £2,591, 596 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−7.4% ▼like-for-like: small discount (95% range −12.1% to −2.5%)
+3%raw gap per m² (before like-for-like)
596sales matched to a certificate
64%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 102 m² against 94 m² for D–G; the most common build period is 2012 onwards for C+ and 1967–1975 for D–G; 73% of C+ and 83% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+3%—
Whole price, nothing held equal−2.6%−9.6% to +5.0%
Same floor area−2.4%−6.6% to +1.9%
+ same property type−2.4%−6.3% to +1.6%
+ same build period−0.5%−6.2% to +5.6%
+ same year of sale−7.4%−12.1% to −2.5%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in SK23 9

EPC band (last certificate before sale)SalesMedian £ per m²
B157£2,680
C117£2,681
D211£2,557
E86£2,673
F18£2,545
G7too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached114£2,817119£3,190
Semi-detached87£2,405149£2,548
Terraced65£2,44949£2,245
Flat / maisonette8—5—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector SK23 9596−7.4%−12.1% to −2.5%
District SK233,626+0.8%−1.3% to +2.9%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in SK23 9 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)46 (1,020 meters)
Median gas use per meter (median of postcodes)13,399 kWh
Gas-heated homes with an EPC727
Energy implied by their certificates (median)17,602 kWh
Metered gas as a share of the certificate figure (median of 45 postcodes)64% (middle half 54%–73%)

Certificates by band imply: B 8,485 kWh (156 homes) · C 15,145 kWh (203 homes) · D 22,075 kWh (290 homes) · E 36,573 kWh (71 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in SK23 9?

About 640 of the 727 gas-heated homes with an energy certificate in SK23 9 (88%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 3 of the 27 local substations would fill up before every gas-heated home they supply could switch; 2 are already at or over capacity.

Local (street) substations serving homes in the sector27
Already at or over capacity2 (7%)
Their combined spare capacity (demand headroom)≈ 2,790 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,640
Gas-heated homes with an EPC on these substations727
Of them, could switch within the spare capacity≈ 640 (88%)
…if each heat pump adds 3 kW (a cold snap)≈ 490 (67%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

596 of 616 house and flat sales in the sector since 2015 (97%) were matched to a certificate.

How this is calculated

Caveats