Does a C-or-better EPC sell for more in SK22 2 (High Peak)?

No measurable EPC premium here. In postcode sector SK22 2 (High Peak), comparing like with like — same floor area, property type, build period and year of sale — the difference is −3.8% (95% range −8.8% to +1.4%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 6% less per square metre than D–G homes (median £2,791 vs £2,966, 367 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−3.8%like-for-like: no measurable difference (95% range −8.8% to +1.4%)
−6%raw gap per m² (before like-for-like)
367sales matched to a certificate
57%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 94 m² against 88 m² for D–G; the most common build period is 1900–1929 for C+ and before 1900 for D–G; 38% of C+ and 56% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−6%—
Whole price, nothing held equal−7.0%−16.2% to +3.1%
Same floor area−5.4%−11.4% to +0.9%
+ same property type−1.1%−6.6% to +4.7%
+ same build period+1.3%−4.8% to +7.9%
+ same year of sale−3.8%−8.8% to +1.4%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in SK22 2

EPC band (last certificate before sale)SalesMedian £ per m²
B14£2,763
C109£2,796
D175£2,982
E56£2,941
F11£2,467
G2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached30£3,37867£3,139
Semi-detached17£2,67470£2,961
Terraced53£2,84997£2,864
Flat / maisonette23£2,35610£2,763

Compared with the wider area

AreaSalesLike-for-like95% range
Sector SK22 2367−3.8%−8.8% to +1.4%
District SK222,208+1.8%−0.3% to +4.0%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in SK22 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)50 (944 meters)
Median gas use per meter (median of postcodes)11,678 kWh
Gas-heated homes with an EPC601
Energy implied by their certificates (median)20,093 kWh
Metered gas as a share of the certificate figure (median of 48 postcodes)57% (middle half 50%–68%)

Certificates by band imply: B 9,506 kWh (25 homes) · C 14,954 kWh (185 homes) · D 20,639 kWh (296 homes) · E 35,190 kWh (86 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in SK22 2?

About 390 of the 601 gas-heated homes with an energy certificate in SK22 2 (64%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 5 of the 26 local substations would fill up before every gas-heated home they supply could switch; 1 is already at or over capacity.

Local (street) substations serving homes in the sector26
Already at or over capacity1 (4%)
Their combined spare capacity (demand headroom)≈ 1,790 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,050
Gas-heated homes with an EPC on these substations601
Of them, could switch within the spare capacity≈ 390 (64%)
…if each heat pump adds 3 kW (a cold snap)≈ 320 (54%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

367 of 403 house and flat sales in the sector since 2015 (91%) were matched to a certificate.

How this is calculated

Caveats