Does a C-or-better EPC sell for more in S66 3 (Rotherham)?

A small premium for a better EPC here. In postcode sector S66 3 (Rotherham), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 2.8% more (95% range +0.2% to +5.5%). The raw gap is different: C+ homes sold for 0% more per square metre than D–G homes (median £2,102 vs £2,099, 1,024 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+2.8% ▲like-for-like: small premium (95% range +0.2% to +5.5%)
0%raw gap per m² (before like-for-like)
1,024sales matched to a certificate
64%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 89 m² against 78 m² for D–G; the most common build period is 2003–2006 for C+ and 1983–1990 for D–G; 74% of C+ and 81% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)0%—
Whole price, nothing held equal+25.1%+19.1% to +31.5%
Same floor area+7.5%+3.2% to +12.1%
+ same property type+19.7%+15.6% to +23.9%
+ same build period+11.6%+7.6% to +15.7%
+ same year of sale+2.8%+0.2% to +5.5%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in S66 3

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B58£1,921
C526£2,149
D364£2,176
E68£1,868
F4too few
G2too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached260£2,486192£2,558
Semi-detached171£2,018161£1,739
Terraced103£1,92381£1,875
Flat / maisonette52£1,7374—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector S66 31,024+2.8%+0.2% to +5.5%
District S667,408+1.4%−0.2% to +3.1%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in S66 3 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)105 (2,433 meters)
Median gas use per meter (median of postcodes)10,667 kWh
Gas-heated homes with an EPC1,582
Energy implied by their certificates (median)16,657 kWh
Metered gas as a share of the certificate figure (median of 104 postcodes)64% (middle half 57%–74%)

Certificates by band imply: B 8,538 kWh (68 homes) · C 14,420 kWh (730 homes) · D 18,522 kWh (621 homes) · E 24,794 kWh (138 homes) · F 33,398 kWh (17 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in S66 3?

About 1,280 of the 1,578 gas-heated homes with an energy certificate in S66 3 (81%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 5 of the 15 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector15
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 6,040 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 3,550
Gas-heated homes with an EPC on these substations1,578
Of them, could switch within the spare capacity≈ 1,280 (81%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,080 (69%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

1,024 of 1,071 house and flat sales in the sector since 2015 (96%) were matched to a certificate.