EPC Price Check

Does a C-or-better EPC sell for more in S10 4 (Sheffield)?

No measurable EPC premium here. In postcode sector S10 4 (Sheffield), comparing like with like — same floor area, property type, build period and year of sale — the difference is −1.5% (95% range −3.7% to +0.8%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 5% less per square metre than D–G homes (median £3,214 vs £3,394, 1,022 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−1.5%like-for-like: no measurable difference (95% range −3.7% to +0.8%)
−5%raw gap per m² (before like-for-like)
1,022sales matched to a certificate
69%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 105 m² against 104 m² for D–G; both groups are most often built in 1950–1966; 65% of C+ and 86% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−5%—
Whole price, nothing held equal−3.9%−9.8% to +2.3%
Same floor area−6.8%−9.9% to −3.7%
+ same property type+3.6%+0.5% to +6.8%
+ same build period+3.0%−0.1% to +6.2%
+ same year of sale−1.5%−3.7% to +0.8%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in S10 4

EPC band (last certificate before sale)SalesMedian £ per m²
B50£3,212
C343£3,216
D478£3,397
E139£3,394
F11£2,897
G1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached114£3,539243£3,613
Semi-detached141£3,500301£3,408
Terraced35£3,11146£3,036
Flat / maisonette103£2,55339£2,509

Compared with the wider area

AreaSalesLike-for-like95% range
Sector S10 41,022−1.5%−3.7% to +0.8%
District S106,579+0.9%−0.4% to +2.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in S10 4 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)116 (2,866 meters)
Median gas use per meter (median of postcodes)16,573 kWh
Gas-heated homes with an EPC1,734
Energy implied by their certificates (median)22,002 kWh
Metered gas as a share of the certificate figure (median of 113 postcodes)69% (middle half 63%–75%)

Certificates by band imply: B 11,984 kWh (93 homes) · C 15,611 kWh (660 homes) · D 24,101 kWh (779 homes) · E 34,840 kWh (184 homes) · F 51,653 kWh (15 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in S10 4?

Yes, on Northern Powergrid's figures: the local substations serving S10 4 have enough spare capacity for all 1,395 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 21 local substations would fill up first.

Local (street) substations serving homes in the sector21
Already at or over capacity1 (5%)
Their combined spare capacity (demand headroom)≈ 8,450 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,970
Gas-heated homes with an EPC on these substations1,395 (80% of the sector's)
Of them, could switch within the spare capacity≈ 1,395 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,300 (93%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

1,022 of 1,080 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats