EPC Price Check

Does a C-or-better EPC sell for more in RM1 1 (Havering)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector RM1 1 (Havering), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district RM1 as a whole the like-for-like difference is −2.1% (95% range −4.0% to −0.2%). The raw gap is different: C+ homes sold for 0% more per square metre than D–G homes (median £4,229 vs £4,216, 289 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−2.1%like-for-like in district RM1 (95% range −4.0% to −0.2%); too few sales in this sector
0%raw gap per m² (before like-for-like)
289sales matched to a certificate
69%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 60 m² against 62 m² for D–G; both groups are most often built in 1996–2002; 0% of C+ and 13% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in RM1 1

EPC band (last certificate before sale)SalesMedian £ per m²
B71£3,409
C179£4,459
D29£4,351
E9too few
F1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Semi-detached1—5—
Terraced1—5—
Flat / maisonette248£4,17229£4,130

Compared with the wider area

AreaSalesLike-for-like95% range
Sector RM1 1289too few—
District RM13,764−2.1%−4.0% to −0.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in RM1 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)26 (572 meters)
Median gas use per meter (median of postcodes)7,676 kWh
Gas-heated homes with an EPC543
Energy implied by their certificates (median)7,655 kWh
Metered gas as a share of the certificate figure (median of 23 postcodes)69% (middle half 62%–95%)

Certificates by band imply: B 4,975 kWh (138 homes) · C 7,545 kWh (265 homes) · D 15,868 kWh (114 homes) · E 23,756 kWh (24 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in RM1 1?

About 480 of the 493 gas-heated homes with an energy certificate in RM1 1 (98%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 1 of the 27 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector27
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 12,440 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 7,320
Gas-heated homes with an EPC on these substations493 (91% of the sector's)
Of them, could switch within the spare capacity≈ 480 (98%)
…if each heat pump adds 3 kW (a cold snap)≈ 460 (93%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

289 of 325 house and flat sales in the sector since 2015 (89%) were matched to a certificate.

How this is calculated

Caveats