EPC Price Check

Does a C-or-better EPC sell for more in NR1 1 (Norwich)?

A small premium for a better EPC here. In postcode sector NR1 1 (Norwich), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.4% more (95% range +1.8% to +7.1%). The raw gap is bigger: C+ homes sold for 7% more per square metre than D–G homes (median £2,968 vs £2,761, 1,952 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.4% ▲like-for-like: small premium (95% range +1.8% to +7.1%)
+7%raw gap per m² (before like-for-like)
1,952sales matched to a certificate
55%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 61 m² against 74 m² for D–G; the most common build period is 2012 onwards for C+ and before 1900 for D–G; 2% of C+ and 8% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+7%—
Whole price, nothing held equal−10.3%−14.0% to −6.4%
Same floor area+7.4%+4.8% to +10.1%
+ same property type+9.5%+6.6% to +12.4%
+ same build period+5.5%+2.8% to +8.3%
+ same year of sale+4.4%+1.8% to +7.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in NR1 1

EPC band (last certificate before sale)SalesMedian £ per m²
B551£3,115
C920£2,899
D356£2,810
E108£2,613
F13£2,647
G4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached9—14£3,052
Semi-detached27£2,97524£2,903
Terraced195£2,869223£2,670
Flat / maisonette1,240£2,980220£2,824

Compared with the wider area

AreaSalesLike-for-like95% range
Sector NR1 11,952+4.4%+1.8% to +7.1%
District NR15,788+1.8%+0.5% to +3.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in NR1 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)90 (2,046 meters)
Median gas use per meter (median of postcodes)7,880 kWh
Gas-heated homes with an EPC1,769
Energy implied by their certificates (median)9,794 kWh
Metered gas as a share of the certificate figure (median of 86 postcodes)55% (middle half 48%–65%)

Certificates by band imply: B 6,211 kWh (247 homes) · C 8,102 kWh (998 homes) · D 18,535 kWh (419 homes) · E 28,889 kWh (98 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in NR1 1?

About 1,270 of the 1,736 gas-heated homes with an energy certificate in NR1 1 (73%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 4 of the 33 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector33
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 13,150 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 7,730
Gas-heated homes with an EPC on these substations1,736 (98% of the sector's)
Of them, could switch within the spare capacity≈ 1,270 (73%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,100 (63%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,952 of 2,114 house and flat sales in the sector since 2015 (92%) were matched to a certificate.

How this is calculated

Caveats