EPC Price Check

Does a C-or-better EPC sell for more in NE15 0 (Northumberland)?

No measurable EPC premium here. In postcode sector NE15 0 (Northumberland), comparing like with like — same floor area, property type, build period and year of sale — the difference is +5.1% (95% range −1.0% to +11.7%): the EPC band itself is not reflected in sale prices here. The raw gap is different: C+ homes sold for 3% more per square metre than D–G homes (median £2,679 vs £2,606, 268 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+5.1%like-for-like: no measurable difference (95% range −1.0% to +11.7%)
+3%raw gap per m² (before like-for-like)
268sales matched to a certificate
67%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 126 m² against 99 m² for D–G; both groups are most often built in 1950–1966; 78% of C+ and 78% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+3%—
Whole price, nothing held equal+25.2%+8.6% to +44.3%
Same floor area+7.2%−0.5% to +15.6%
+ same property type+9.9%+2.6% to +17.6%
+ same build period+7.6%+0.4% to +15.4%
+ same year of sale+5.1%−1.0% to +11.7%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in NE15 0

EPC band (last certificate before sale)SalesMedian £ per m²
B11£2,969
C52£2,670
D130£2,681
E56£2,587
F18£2,363
G1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached28£2,93479£2,915
Semi-detached21£2,31981£2,589
Terraced10£2,84736£2,234
Flat / maisonette4—9—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector NE15 0268+5.1%−1.0% to +11.7%
District NE155,425−1.6%−3.7% to +0.4%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in NE15 0 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)24 (557 meters)
Median gas use per meter (median of postcodes)14,988 kWh
Gas-heated homes with an EPC448
Energy implied by their certificates (median)21,029 kWh
Metered gas as a share of the certificate figure (median of 23 postcodes)67% (middle half 60%–72%)

Certificates by band imply: B 15,141 kWh (16 homes) · C 16,747 kWh (159 homes) · D 21,508 kWh (219 homes) · E 33,886 kWh (50 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in NE15 0?

About 350 of the 360 gas-heated homes with an energy certificate in NE15 0 (97%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 1 of the 17 local substations would fill up before every gas-heated home they supply could switch; 1 is already at or over capacity.

Local (street) substations serving homes in the sector17
Already at or over capacity1 (6%)
Their combined spare capacity (demand headroom)≈ 1,940 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,140
Gas-heated homes with an EPC on these substations360 (80% of the sector's)
Of them, could switch within the spare capacity≈ 350 (97%)
…if each heat pump adds 3 kW (a cold snap)≈ 250 (68%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

268 of 304 house and flat sales in the sector since 2015 (88%) were matched to a certificate.

How this is calculated

Caveats