EPC Price Check

Does a C-or-better EPC sell for more in ME9 8 (Swale)?

No premium here: C+ homes sold for slightly less. In postcode sector ME9 8 (Swale), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.3% less (95% range −7.1% to −1.4%). The raw gap is bigger: C+ homes sold for 8% less per square metre than D–G homes (median £3,347 vs £3,622, 1,423 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−4.3% ▼like-for-like: small discount (95% range −7.1% to −1.4%)
−8%raw gap per m² (before like-for-like)
1,423sales matched to a certificate
69%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 91 m² against 99 m² for D–G; the most common build period is 2012 onwards for C+ and 1996–2002 for D–G; 65% of C+ and 82% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−8%—
Whole price, nothing held equal−13.6%−17.4% to −9.6%
Same floor area−8.4%−11.0% to −5.8%
+ same property type−5.5%−8.0% to −3.0%
+ same build period−0.8%−4.6% to +3.1%
+ same year of sale−4.3%−7.1% to −1.4%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in ME9 8

EPC band (last certificate before sale)SalesMedian £ per m²
A12£4,039
B448£3,320
C524£3,333
D334£3,621
E76£3,407
F25£3,837
G4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached357£3,449193£3,826
Semi-detached286£3,529169£3,410
Terraced251£3,13768£3,645
Flat / maisonette90£2,7839—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector ME9 81,423−4.3%−7.1% to −1.4%
District ME93,677−3.4%−5.0% to −1.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in ME9 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)137 (2,381 meters)
Median gas use per meter (median of postcodes)10,769 kWh
Gas-heated homes with an EPC1,909
Energy implied by their certificates (median)13,217 kWh
Metered gas as a share of the certificate figure (median of 131 postcodes)69% (middle half 59%–81%)

Certificates by band imply: A 3,185 kWh (26 homes) · B 6,177 kWh (476 homes) · C 12,982 kWh (798 homes) · D 20,145 kWh (491 homes) · E 31,793 kWh (102 homes) · F 51,939 kWh (16 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in ME9 8?

About 970 of the 1,358 gas-heated homes with an energy certificate in ME9 8 (71%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 9 of the 29 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector29
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 4,760 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,800
Gas-heated homes with an EPC on these substations1,358 (71% of the sector's)
Of them, could switch within the spare capacity≈ 970 (71%)
…if each heat pump adds 3 kW (a cold snap)≈ 690 (51%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,423 of 1,522 house and flat sales in the sector since 2015 (93%) were matched to a certificate.

How this is calculated

Caveats