EPC Price Check

Does a C-or-better EPC sell for more in M40 5 (Manchester)?

No measurable EPC premium here. In postcode sector M40 5 (Manchester), comparing like with like — same floor area, property type, build period and year of sale — the difference is +0.6% (95% range −3.2% to +4.6%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 16% more per square metre than D–G homes (median £1,986 vs £1,712, 453 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+0.6%like-for-like: no measurable difference (95% range −3.2% to +4.6%)
+16%raw gap per m² (before like-for-like)
453sales matched to a certificate
64%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 84 m² against 79 m² for D–G; both groups are most often built in 1930–1949; 65% of C+ and 70% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+16%—
Whole price, nothing held equal+18.2%+10.0% to +27.1%
Same floor area+15.5%+8.4% to +23.0%
+ same property type+16.7%+9.9% to +24.0%
+ same build period+11.8%+3.3% to +20.9%
+ same year of sale+0.6%−3.2% to +4.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in M40 5

EPC band (last certificate before sale)SalesMedian £ per m²
B31£1,805
C131£2,062
D240£1,754
E42£1,471
F8too few
G1too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached14£2,16613£2,366
Semi-detached91£2,192192£1,779
Terraced55£1,69883£1,453
Flat / maisonette2—3—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector M40 5453+0.6%−3.2% to +4.6%
District M404,318−0.1%−2.0% to +1.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in M40 5 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)116 (1,876 meters)
Median gas use per meter (median of postcodes)9,577 kWh
Gas-heated homes with an EPC1,367
Energy implied by their certificates (median)14,634 kWh
Metered gas as a share of the certificate figure (median of 113 postcodes)64% (middle half 57%–75%)

Certificates by band imply: B 6,793 kWh (125 homes) · C 12,210 kWh (613 homes) · D 17,921 kWh (539 homes) · E 26,281 kWh (84 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in M40 5?

About 1,020 of the 1,366 gas-heated homes with an energy certificate in M40 5 (75%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 6 of the 16 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector16
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 8,870 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,220
Gas-heated homes with an EPC on these substations1,366
Of them, could switch within the spare capacity≈ 1,020 (75%)
…if each heat pump adds 3 kW (a cold snap)≈ 830 (61%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

453 of 516 house and flat sales in the sector since 2015 (88%) were matched to a certificate.

How this is calculated

Caveats