EPC Price Check

Does a C-or-better EPC sell for more in M30 0 (Salford)?

A small premium for a better EPC here. In postcode sector M30 0 (Salford), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 3.6% more (95% range +0.2% to +7.1%). The raw gap is bigger: C+ homes sold for 56% more per square metre than D–G homes (median £2,682 vs £1,716, 1,314 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+3.6% ▲like-for-like: small premium (95% range +0.2% to +7.1%)
+56%raw gap per m² (before like-for-like)
1,314sales matched to a certificate
62%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 81 m² against 83 m² for D–G; the most common build period is 2012 onwards for C+ and 1900–1929 for D–G; 50% of C+ and 29% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+56%—
Whole price, nothing held equal+37.3%+31.0% to +43.9%
Same floor area+43.3%+37.8% to +49.0%
+ same property type+33.4%+28.4% to +38.6%
+ same build period+16.8%+11.5% to +22.4%
+ same year of sale+3.6%+0.2% to +7.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in M30 0

EPC band (last certificate before sale)SalesMedian £ per m²
B236£2,943
C302£2,294
D544£1,873
E182£1,462
F35£1,258
G15£963

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached114£3,03630£2,207
Semi-detached157£2,939196£2,106
Terraced182£2,249519£1,561
Flat / maisonette85£1,87531£1,696

Compared with the wider area

AreaSalesLike-for-like95% range
Sector M30 01,314+3.6%+0.2% to +7.1%
District M305,805+0.7%−1.2% to +2.5%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in M30 0 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)220 (4,581 meters)
Median gas use per meter (median of postcodes)7,958 kWh
Gas-heated homes with an EPC3,705
Energy implied by their certificates (median)12,324 kWh
Metered gas as a share of the certificate figure (median of 216 postcodes)62% (middle half 54%–75%)

Certificates by band imply: B 6,309 kWh (534 homes) · C 10,318 kWh (1,640 homes) · D 17,872 kWh (1,198 homes) · E 28,555 kWh (304 homes) · F 41,890 kWh (25 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in M30 0?

About 2,970 of the 3,705 gas-heated homes with an energy certificate in M30 0 (80%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 9 of the 36 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector36
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 17,290 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 10,170
Gas-heated homes with an EPC on these substations3,705
Of them, could switch within the spare capacity≈ 2,970 (80%)
…if each heat pump adds 3 kW (a cold snap)≈ 2,350 (63%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,314 of 1,393 house and flat sales in the sector since 2015 (94%) were matched to a certificate.

How this is calculated

Caveats