EPC Price Check

Does a C-or-better EPC sell for more in M16 8 (Manchester)?

A small premium for a better EPC here. In postcode sector M16 8 (Manchester), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 4.1% more (95% range +1.0% to +7.3%). The raw gap is different: C+ homes sold for 3% more per square metre than D–G homes (median £2,828 vs £2,744, 1,237 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+4.1% ▲like-for-like: small premium (95% range +1.0% to +7.3%)
+3%raw gap per m² (before like-for-like)
1,237sales matched to a certificate
63%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 68 m² against 89 m² for D–G; the most common build period is 2003–2006 for C+ and 1900–1929 for D–G; 16% of C+ and 41% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+3%—
Whole price, nothing held equal−12.3%−17.4% to −6.9%
Same floor area+3.5%0.0% to +7.1%
+ same property type+7.9%+4.5% to +11.4%
+ same build period+10.4%+6.5% to +14.5%
+ same year of sale+4.1%+1.0% to +7.3%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in M16 8

EPC band (last certificate before sale)SalesMedian £ per m²
A1too few
B105£2,769
C444£2,836
D474£2,867
E178£2,500
F29£2,391
G6too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached24£3,51437£3,103
Semi-detached63£3,020245£2,869
Terraced141£2,913143£2,786
Flat / maisonette322£2,637262£2,563

Compared with the wider area

AreaSalesLike-for-like95% range
Sector M16 81,237+4.1%+1.0% to +7.3%
District M163,732+1.8%−0.3% to +3.9%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in M16 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)175 (3,640 meters)
Median gas use per meter (median of postcodes)10,734 kWh
Gas-heated homes with an EPC3,155
Energy implied by their certificates (median)13,250 kWh
Metered gas as a share of the certificate figure (median of 169 postcodes)63% (middle half 50%–75%)

Certificates by band imply: B 7,146 kWh (175 homes) · C 9,074 kWh (1,446 homes) · D 18,765 kWh (1,115 homes) · E 35,632 kWh (378 homes) · F 52,177 kWh (39 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in M16 8?

About 2,760 of the 3,154 gas-heated homes with an energy certificate in M16 8 (88%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 6 of the 23 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector23
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 11,300 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 6,650
Gas-heated homes with an EPC on these substations3,154
Of them, could switch within the spare capacity≈ 2,760 (88%)
…if each heat pump adds 3 kW (a cold snap)≈ 2,000 (64%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

1,237 of 1,417 house and flat sales in the sector since 2015 (87%) were matched to a certificate.

How this is calculated

Caveats