EPC Price Check

Does a C-or-better EPC sell for more in LS15 9 (Leeds)?

No measurable EPC premium here. In postcode sector LS15 9 (Leeds), comparing like with like — same floor area, property type, build period and year of sale — the difference is +0.4% (95% range −1.8% to +2.6%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 1% more per square metre than D–G homes (median £3,073 vs £3,057, 627 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+0.4%like-for-like: no measurable difference (95% range −1.8% to +2.6%)
+1%raw gap per m² (before like-for-like)
627sales matched to a certificate
59%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 79 m² against 73 m² for D–G; both groups are most often built in 1983–1990; 63% of C+ and 64% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+1%—
Whole price, nothing held equal+15.5%+9.0% to +22.5%
Same floor area+2.5%−1.4% to +6.7%
+ same property type+7.3%+3.8% to +11.0%
+ same build period+3.8%+0.5% to +7.3%
+ same year of sale+0.4%−1.8% to +2.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in LS15 9

EPC band (last certificate before sale)SalesMedian £ per m²
B16£2,700
C279£3,077
D306£3,100
E22£2,774
F4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached111£3,333143£3,329
Semi-detached76£3,01270£3,173
Terraced101£2,838118£2,667
Flat / maisonette7—1—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector LS15 9627+0.4%−1.8% to +2.6%
District LS156,223+0.6%−0.6% to +1.9%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in LS15 9 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)89 (1,622 meters)
Median gas use per meter (median of postcodes)10,181 kWh
Gas-heated homes with an EPC1,008
Energy implied by their certificates (median)16,088 kWh
Metered gas as a share of the certificate figure (median of 88 postcodes)59% (middle half 53%–66%)

Certificates by band imply: B 10,377 kWh (49 homes) · C 13,373 kWh (441 homes) · D 17,758 kWh (463 homes) · E 26,636 kWh (51 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in LS15 9?

About 850 of the 946 gas-heated homes with an energy certificate in LS15 9 (90%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 3 of the 17 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector17
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 8,700 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,120
Gas-heated homes with an EPC on these substations946 (94% of the sector's)
Of them, could switch within the spare capacity≈ 850 (90%)
…if each heat pump adds 3 kW (a cold snap)≈ 780 (83%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

627 of 657 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats