EPC Price Check

Does a C-or-better EPC sell for more in LA23 1 (Westmorland and Furness)?

No premium here: C+ homes sold for slightly less. In postcode sector LA23 1 (Westmorland and Furness), comparing like with like — same floor area, property type, build period and year of sale — homes rated C or better sold for 10.9% less (95% range −17.7% to −3.6%). The raw gap is different: C+ homes sold for 3% less per square metre than D–G homes (median £3,664 vs £3,792, 456 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−10.9% ▼like-for-like: small discount (95% range −17.7% to −3.6%)
−3%raw gap per m² (before like-for-like)
456sales matched to a certificate
57%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 83 m² against 96 m² for D–G; the most common build period is 1983–1990 for C+ and before 1900 for D–G; 34% of C+ and 42% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)−3%—
Whole price, nothing held equal−16.4%−27.7% to −3.4%
Same floor area−7.3%−14.0% to −0.1%
+ same property type−3.1%−9.7% to +4.1%
+ same build period−5.7%−13.1% to +2.2%
+ same year of sale−10.9%−17.7% to −3.6%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in LA23 1

EPC band (last certificate before sale)SalesMedian £ per m²
B19£3,168
C109£3,696
D186£3,590
E98£3,939
F38£4,121
G6too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached34£4,170108£4,489
Semi-detached9—31£3,750
Terraced11£3,867104£3,526
Flat / maisonette74£3,25685£3,137

Compared with the wider area

AreaSalesLike-for-like95% range
Sector LA23 1456−10.9%−17.7% to −3.6%
District LA231,605−7.3%−10.8% to −3.7%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in LA23 1 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)71 (904 meters)
Median gas use per meter (median of postcodes)14,201 kWh
Gas-heated homes with an EPC694
Energy implied by their certificates (median)23,223 kWh
Metered gas as a share of the certificate figure (median of 66 postcodes)57% (middle half 47%–72%)

Certificates by band imply: B 11,833 kWh (30 homes) · C 13,788 kWh (201 homes) · D 23,586 kWh (300 homes) · E 39,765 kWh (129 homes) · F 56,050 kWh (31 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in LA23 1?

About 570 of the 693 gas-heated homes with an energy certificate in LA23 1 (82%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 3 of the 74 local substations would fill up before every gas-heated home they supply could switch; 3 are already at or over capacity.

Local (street) substations serving homes in the sector74
Already at or over capacity3 (4%)
Their combined spare capacity (demand headroom)≈ 9,270 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,450
Gas-heated homes with an EPC on these substations693
Of them, could switch within the spare capacity≈ 570 (82%)
…if each heat pump adds 3 kW (a cold snap)≈ 530 (76%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

456 of 515 house and flat sales in the sector since 2015 (89%) were matched to a certificate.

How this is calculated

Caveats