EPC Price Check

Does a C-or-better EPC sell for more in LA22 9 (Westmorland and Furness)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector LA22 9 (Westmorland and Furness), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district LA22 as a whole the like-for-like difference is −7.5% (95% range −12.5% to −2.2%). The raw gap is bigger: C+ homes sold for 23% less per square metre than D–G homes (median £3,627 vs £4,702, 428 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−7.5%like-for-like in district LA22 (95% range −12.5% to −2.2%); too few sales in this sector
−23%raw gap per m² (before like-for-like)
428sales matched to a certificate
51%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 66 m² against 98 m² for D–G; the most common build period is 1983–1990 for C+ and before 1900 for D–G; 21% of C+ and 47% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in LA22 9

EPC band (last certificate before sale)SalesMedian £ per m²
B11£3,977
C96£3,619
D148£4,420
E95£4,948
F59£5,265
G19£5,272

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached14£5,581104£5,441
Semi-detached8—48£4,456
Terraced33£2,874128£4,343
Flat / maisonette52£3,63941£4,323

Compared with the wider area

AreaSalesLike-for-like95% range
Sector LA22 9428too few—
District LA22818−7.5%−12.5% to −2.2%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in LA22 9 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)80 (1,161 meters)
Median gas use per meter (median of postcodes)12,489 kWh
Gas-heated homes with an EPC916
Energy implied by their certificates (median)20,694 kWh
Metered gas as a share of the certificate figure (median of 73 postcodes)51% (middle half 42%–62%)

Certificates by band imply: B 9,331 kWh (60 homes) · C 13,858 kWh (308 homes) · D 24,250 kWh (350 homes) · E 37,041 kWh (161 homes) · F 51,150 kWh (36 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in LA22 9?

About 900 of the 909 gas-heated homes with an energy certificate in LA22 9 (99%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 1 of the 88 local substations would fill up before every gas-heated home they supply could switch; 2 are already at or over capacity.

Local (street) substations serving homes in the sector88
Already at or over capacity2 (2%)
Their combined spare capacity (demand headroom)≈ 10,090 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 5,940
Gas-heated homes with an EPC on these substations909 (99% of the sector's)
Of them, could switch within the spare capacity≈ 900 (99%)
…if each heat pump adds 3 kW (a cold snap)≈ 860 (95%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

428 of 543 house and flat sales in the sector since 2015 (79%) were matched to a certificate.

How this is calculated

Caveats