EPC Price Check

Does a C-or-better EPC sell for more in LA20 6 (Westmorland and Furness)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector LA20 6 (Westmorland and Furness), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district LA20 as a whole the like-for-like difference is −9.4% (95% range −24.6% to +8.8%). The raw gap is different: C+ homes sold for 1% more per square metre than D–G homes (median £2,394 vs £2,361, 161 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−9.4%like-for-like in district LA20 (95% range −24.6% to +8.8%); too few sales in this sector
+1%raw gap per m² (before like-for-like)
161sales matched to a certificate
44%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 113 m² against 117 m² for D–G; the most common build period is 2007–2011 for C+ and before 1900 for D–G; 50% of C+ and 58% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in LA20 6

EPC band (last certificate before sale)SalesMedian £ per m²
A2too few
B1too few
C27£2,371
D47£2,600
E47£2,333
F29£2,151
G8too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached10£2,99053£2,672
Semi-detached5—23£2,440
Terraced13£2,02651£2,171
Flat / maisonette2—4—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector LA20 6161too few—
District LA20161−9.4%−24.6% to +8.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in LA20 6 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)24 (261 meters)
Median gas use per meter (median of postcodes)10,954 kWh
Gas-heated homes with an EPC187
Energy implied by their certificates (median)22,662 kWh
Metered gas as a share of the certificate figure (median of 20 postcodes)44% (middle half 35%–58%)

Certificates by band imply: B 6,910 kWh (18 homes) · C 15,322 kWh (40 homes) · D 23,791 kWh (88 homes) · E 40,078 kWh (32 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in LA20 6?

Yes, on SP Electricity North West's figures: the local substations serving LA20 6 have enough spare capacity for all 187 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 54 local substations would fill up first.

Local (street) substations serving homes in the sector54
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 2,510 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 1,480
Gas-heated homes with an EPC on these substations187
Of them, could switch within the spare capacity≈ 187 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 180 (99%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

161 of 200 house and flat sales in the sector since 2015 (80%) were matched to a certificate.

How this is calculated

Caveats