EPC Price Check

Does a C-or-better EPC sell for more in L39 8 (West Lancashire)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector L39 8 (West Lancashire), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district L39 as a whole the like-for-like difference is −1.0% (95% range −2.6% to +0.6%). The raw gap is bigger: C+ homes sold for 9% less per square metre than D–G homes (median £2,421 vs £2,647, 212 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−1.0%like-for-like in district L39 (95% range −2.6% to +0.6%); too few sales in this sector
−9%raw gap per m² (before like-for-like)
212sales matched to a certificate
61%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 111 m² against 115 m² for D–G; the most common build period is 2012 onwards for C+ and 1900–1929 for D–G; 89% of C+ and 92% of D–G sales are detached or semi-detached houses.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in L39 8

EPC band (last certificate before sale)SalesMedian £ per m²
B23£3,125
C47£2,268
D71£2,619
E38£2,922
F29£2,545
G4too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached33£2,91767£2,835
Semi-detached29£2,25064£2,523
Terraced7—9—
Flat / maisonette1—2—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector L39 8212too few—
District L394,344−1.0%−2.6% to +0.6%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in L39 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)22 (350 meters)
Median gas use per meter (median of postcodes)15,048 kWh
Gas-heated homes with an EPC246
Energy implied by their certificates (median)22,385 kWh
Metered gas as a share of the certificate figure (median of 20 postcodes)61% (middle half 53%–72%)

Certificates by band imply: B 10,303 kWh (34 homes) · C 17,379 kWh (76 homes) · D 25,205 kWh (96 homes) · E 35,788 kWh (31 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in L39 8?

About 240 of the 245 gas-heated homes with an energy certificate in L39 8 (99%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 1 of the 28 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector28
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 3,800 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 2,230
Gas-heated homes with an EPC on these substations245
Of them, could switch within the spare capacity≈ 240 (99%)
…if each heat pump adds 3 kW (a cold snap)≈ 240 (96%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

212 of 241 house and flat sales in the sector since 2015 (88%) were matched to a certificate.

How this is calculated

Caveats