EPC Price Check

Does a C-or-better EPC sell for more in HU2 0 (Kingston upon Hull)?

Too few comparable sales here for a reliable like-for-like figure. In postcode sector HU2 0 (Kingston upon Hull), comparing like with like — same floor area, property type, build period and year of sale — there are too few comparable sales in each group for a reliable figure; for district HU2 as a whole the like-for-like difference is +0.1% (95% range −6.3% to +6.9%). The raw gap is different: C+ homes sold for 9% less per square metre than D–G homes (median £987 vs £1,082, 56 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+0.1%like-for-like in district HU2 (95% range −6.3% to +6.9%); too few sales in this sector
−9%raw gap per m² (before like-for-like)
56sales matched to a certificate
63%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 86 m² against 84 m² for D–G; the most common build period is 1967–1975 for C+ and 1950–1966 for D–G.

This sector has fewer than 150 matched sales, fewer than 30 in one group, or an estimate too imprecise or implausibly large to trust, so the like-for-like comparison is not shown; the district figure is above.

Sold prices by EPC band in HU2 0

EPC band (last certificate before sale)SalesMedian £ per m²
C34£987
D22£1,082

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Terraced33£1,01222£1,082
Flat / maisonette1—0—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector HU2 056too few—
District HU2234+0.1%−6.3% to +6.9%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in HU2 0 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)16 (483 meters)
Median gas use per meter (median of postcodes)7,487 kWh
Gas-heated homes with an EPC499
Energy implied by their certificates (median)12,000 kWh
Metered gas as a share of the certificate figure (median of 16 postcodes)63% (middle half 55%–71%)

Certificates by band imply: B 6,904 kWh (23 homes) · C 11,725 kWh (352 homes) · D 14,050 kWh (119 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in HU2 0?

Yes, on Northern Powergrid's figures: the local substations serving HU2 0 have enough spare capacity for all 485 gas-heated homes with an energy certificate here to switch to a heat pump. None of the 10 local substations would fill up first.

Local (street) substations serving homes in the sector10
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 5,370 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 3,160
Gas-heated homes with an EPC on these substations485 (97% of the sector's)
Of them, could switch within the spare capacity≈ 480 (100%)
…if each heat pump adds 3 kW (a cold snap)≈ 460 (94%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

56 of 60 house and flat sales in the sector since 2015 (93%) were matched to a certificate.

How this is calculated

Caveats