EPC Price Check

Does a C-or-better EPC sell for more in HU19 2 (East Riding of Yorkshire)?

No measurable EPC premium here. In postcode sector HU19 2 (East Riding of Yorkshire), comparing like with like — same floor area, property type, build period and year of sale — the difference is +2.0% (95% range −1.7% to +5.8%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 36% more per square metre than D–G homes (median £1,717 vs £1,263, 1,277 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+2.0%like-for-like: no measurable difference (95% range −1.7% to +5.8%)
+36%raw gap per m² (before like-for-like)
1,277sales matched to a certificate
48%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 79 m² against 92 m² for D–G; the most common build period is 2007–2011 for C+ and 1900–1929 for D–G; 65% of C+ and 48% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+36%—
Whole price, nothing held equal+14.6%+9.3% to +20.1%
Same floor area+24.7%+19.7% to +29.9%
+ same property type+15.7%+11.9% to +19.7%
+ same build period+5.9%+1.1% to +10.8%
+ same year of sale+2.0%−1.7% to +5.8%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in HU19 2

EPC band (last certificate before sale)SalesMedian £ per m²
B24£1,924
C247£1,702
D661£1,300
E283£1,181
F53£1,037
G9too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached70£1,995194£1,688
Semi-detached105£1,702291£1,516
Terraced96£1,506513£1,008
Flat / maisonette0—8—

Compared with the wider area

AreaSalesLike-for-like95% range
Sector HU19 21,277+2.0%−1.7% to +5.8%
District HU191,277+2.0%−1.7% to +5.8%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in HU19 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)131 (2,960 meters)
Median gas use per meter (median of postcodes)9,504 kWh
Gas-heated homes with an EPC2,344
Energy implied by their certificates (median)18,431 kWh
Metered gas as a share of the certificate figure (median of 128 postcodes)48% (middle half 41%–60%)

Certificates by band imply: B 5,465 kWh (71 homes) · C 11,398 kWh (773 homes) · D 20,504 kWh (1,101 homes) · E 32,356 kWh (352 homes) · F 48,769 kWh (42 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in HU19 2?

About 1,660 of the 1,835 gas-heated homes with an energy certificate in HU19 2 (91%) could switch to a heat pump before their local substations run out of spare capacity, on Northern Powergrid's figures. 7 of the 29 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector29
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 7,520 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 4,420
Gas-heated homes with an EPC on these substations1,835 (78% of the sector's)
Of them, could switch within the spare capacity≈ 1,660 (91%)
…if each heat pump adds 3 kW (a cold snap)≈ 1,250 (68%)

How: each substation's spare capacity (transformer headroom in kW, from last year's maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes listed by Northern Powergrid as fed by the substation. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is Northern Powergrid's figure as published on 3 August 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

Supported by Northern Powergrid Open Data.

1,277 of 1,345 house and flat sales in the sector since 2015 (95%) were matched to a certificate.

How this is calculated

Caveats