EPC Price Check

Does a C-or-better EPC sell for more in FY5 2 (Wyre)?

No measurable EPC premium here. In postcode sector FY5 2 (Wyre), comparing like with like — same floor area, property type, build period and year of sale — the difference is +1.1% (95% range −0.9% to +3.1%): the EPC band itself is not reflected in sale prices here. The raw gap is bigger: C+ homes sold for 8% more per square metre than D–G homes (median £2,100 vs £1,947, 2,822 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

+1.1%like-for-like: no measurable difference (95% range −0.9% to +3.1%)
+8%raw gap per m² (before like-for-like)
2,822sales matched to a certificate
55%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 85 m² against 80 m² for D–G; both groups are most often built in 1950–1966; 87% of C+ and 94% of D–G sales are detached or semi-detached houses.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)+8%—
Whole price, nothing held equal+11.2%+7.7% to +14.9%
Same floor area+6.4%+4.1% to +8.8%
+ same property type+6.0%+3.9% to +8.1%
+ same build period+4.7%+2.4% to +7.1%
+ same year of sale+1.1%−0.9% to +3.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in FY5 2

EPC band (last certificate before sale)SalesMedian £ per m²
A3too few
B144£2,153
C531£2,014
D1,623£1,981
E441£1,767
F72£1,852
G8too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Detached253£2,149549£2,150
Semi-detached337£2,0481,457£1,903
Terraced67£2,102114£1,702
Flat / maisonette21£1,64424£1,501

Compared with the wider area

AreaSalesLike-for-like95% range
Sector FY5 22,822+1.1%−0.9% to +3.1%
District FY510,551+1.2%+0.1% to +2.3%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in FY5 2 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)261 (5,493 meters)
Median gas use per meter (median of postcodes)10,312 kWh
Gas-heated homes with an EPC3,654
Energy implied by their certificates (median)18,382 kWh
Metered gas as a share of the certificate figure (median of 252 postcodes)55% (middle half 49%–60%)

Certificates by band imply: B 8,191 kWh (151 homes) · C 14,407 kWh (889 homes) · D 18,690 kWh (2,047 homes) · E 29,028 kWh (503 homes) · F 39,372 kWh (56 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in FY5 2?

About 3,270 of the 3,654 gas-heated homes with an energy certificate in FY5 2 (90%) could switch to a heat pump before their local substations run out of spare capacity, on SP Electricity North West's figures. 8 of the 31 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector31
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 15,290 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 8,990
Gas-heated homes with an EPC on these substations3,654
Of them, could switch within the spare capacity≈ 3,270 (90%)
…if each heat pump adds 3 kW (a cold snap)≈ 2,680 (73%)

How: each substation's spare capacity (transformer demand headroom in kVA, from estimated maximum demand) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose nearest SP Electricity North West substation it is (supply areas are not published). Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is SP Electricity North West's figure as published on 24 March 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

2,822 of 2,931 house and flat sales in the sector since 2015 (96%) were matched to a certificate.

How this is calculated

Caveats