EPC Price Check

Does a C-or-better EPC sell for more in EC2Y 8 (City of London)?

No measurable EPC premium here. In postcode sector EC2Y 8 (City of London), comparing like with like — same floor area, property type, build period and year of sale — the difference is −2.0% (95% range −6.0% to +2.1%): the EPC band itself is not reflected in sale prices here. The raw gap is different: C+ homes sold for 0% less per square metre than D–G homes (median £12,908 vs £12,964, 397 sales 2015–2026), mostly because they are different homes. Across England and Wales the like-for-like figure is +1.2%. Data: HM Land Registry Price Paid to 30 September 2026 matched to the EPC register.

Data: sales January 2015 – September 2026, EPC register November 2026, gas 2024 · calculated 5 November 2026 · Methodology and sources

−2.0%like-for-like: no measurable difference (95% range −6.0% to +2.1%)
0%raw gap per m² (before like-for-like)
397sales matched to a certificate
88%metered gas, % of certificate estimate (rough)

From the raw gap to like-for-like

The homes are not alike: C+ homes here have a median floor area of 65 m² against 71 m² for D–G; both groups are most often built in 1967–1975.

Comparing C+ with D–G homes…Difference95% range
Raw gap per m² (medians)0%—
Whole price, nothing held equal−11.6%−18.5% to −4.0%
Same floor area−3.6%−7.3% to +0.2%
+ same property type−3.7%−7.4% to +0.2%
+ same build period−0.3%−4.1% to +3.6%
+ same year of sale−2.0%−6.0% to +2.1%

The first row compares median prices per m²; the second compares whole prices; each later row adds one more thing that must be equal, ending with the like-for-like premium (regression of log price; build period from the certificate, 12 bands). The raw gap per m² and the whole-price gap differ because C+ and D–G homes differ in size.

Sold prices by EPC band in EC2Y 8

EPC band (last certificate before sale)SalesMedian £ per m²
B21£13,000
C179£12,907
D124£12,961
E53£12,808
F12£13,540
G8too few

A median is shown when a band has at least 10 sales.

C or better vs D–G, by property type

TypeC+ salesC+ £/m²D–G salesD–G £/m²
Terraced0—2—
Flat / maisonette200£12,908195£12,964

Compared with the wider area

AreaSalesLike-for-like95% range
Sector EC2Y 8397−2.0%−6.0% to +2.1%
District EC2Y480−1.7%−5.6% to +2.4%
England and Wales1,000,000 (sample)+1.2%+0.9% to +1.5%

Average gas use in EC2Y 8 (2024): meters vs certificates

A rough comparison: the certificate figure is an upper-bound estimate (primary energy including lighting, converted with one factor), so treat the share as an order of magnitude.

Postcodes with published gas data (5+ meters)3 (50 meters)
Median gas use per meter (median of postcodes)9,637 kWh
Gas-heated homes with an EPC65
Energy implied by their certificates (median)5,982 kWh
Metered gas as a share of the certificate figure (median of 2 postcodes)88% (middle half 74%–102%)

Certificates by band imply: B 4,867 kWh (30 homes) · C 7,317 kWh (24 homes). Across England and Wales, real use is much closer to the certificate for A–C homes than for D–G homes, so the saving an upgrade promises is usually smaller than the certificate suggests.

Certificate energy = primary energy per m² × floor area ÷ 1.13, for homes whose latest certificate shows mains gas heating; it also covers lighting and other uses, so it is an upper bound for gas. DESNZ gas is weather-corrected and covers all meters in the postcode, with or without a certificate.

Can the local grid take heat pumps in EC2Y 8?

About 60 of the 63 gas-heated homes with an energy certificate in EC2Y 8 (89%) could switch to a heat pump before their local substations run out of spare capacity, on UK Power Networks' figures. 3 of the 36 local substations would fill up before every gas-heated home they supply could switch.

Local (street) substations serving homes in the sector36
Already at or over capacity0 (0%)
Their combined spare capacity (demand headroom)≈ 14,220 kVA
Heat pumps that spare capacity could take, at 1.7 kW each≈ 8,360
Gas-heated homes with an EPC on these substations63 (97% of the sector's)
Of them, could switch within the spare capacity≈ 60 (89%)
…if each heat pump adds 3 kW (a cold snap)≈ 50 (86%)

How: each substation's spare capacity (UK Power Networks publishes utilisation in 20% bands; we take the low end of the spare-capacity band) is divided by 1.7 kW, the extra winter peak one heat pump adds once many are spread over a street; a substation can take as many heat pumps as that allows, shared among the gas-heated homes on all its postcodes whose centre lies inside the substation's published supply area. Some substations also serve neighbouring sectors, so their whole capacity is counted here and there. Spare capacity is UK Power Networks' figure as published on 15 June 2026; network operators must still be told about each heat pump, and a full substation means reinforcement (usually a delay), not a refusal. Homes without an energy certificate are not counted. All areas and the method.

397 of 866 house and flat sales in the sector since 2015 (46%) were matched to a certificate.

How this is calculated

Caveats